D
Dillon GibsonAug 15, 2025
What to do if Veco Compressor attempts to start, then stops soon after?
- CChristopher BakerAug 15, 2025
If your Veco Compressor starts and then stops, consider these potential causes: * **Power Supply**: The most likely cause is a faulty or inadequate power supply. Monitor the supply voltage at the controller's power terminals before, during, and after start attempts. It should not drop below threshold levels. Check the power supply, ground connections, wiring size and charge the batteries if necessary. * **Relay or Unauthorized Component**: A faulty fan or pump relay, or an unauthorized component, could be the issue. Remove the connectors from the F and + terminals on the controller and try restarting. Note the maximum current draw on these terminals is limited to 0.7 amps at 12v. * **Refrigerant Couplings**: Check that all refrigerant couplings are properly made.