Frigoboat
Marine Refrigeration Systems
---------------------------------------------------------------
Installation & Instruction Manual
For All Models:
Air Cooled, Pumped-Water Cooled,
Keel Cooled, and Keel-plus-Air Cooled
(Systems using Secop (formally Danfoss) BD 35 or BD 50 compressors)
It is important to read this manual thoroughly before
installing and operating a Frigoboat system.
Veco NA
301.352.6962
info@veco-na.com
Rev 39 – 02/2019

Questions and Answers

  • R
    Robert WilcoxAug 9, 2025
    What to do if Veco Compressor attempts to start, then stops soon after?
    • K
      Karen RogersAug 9, 2025
      If your Veco Compressor starts and then stops, consider these potential causes: * **Power Supply**: The most likely cause is a faulty or inadequate power supply. Monitor the supply voltage at the controller's power terminals before, during, and after start attempts. It should not drop below threshold levels. Check the power supply, ground connections, wiring size and charge the batteries if necessary. * **Relay or Unauthorized Component**: A faulty fan or pump relay, or an unauthorized component, could be the issue. Remove the connectors from the F and + terminals on the controller and try restarting. Note the maximum current draw on these terminals is limited to 0.7 amps at 12v. * **Refrigerant Couplings**: Check that all refrigerant couplings are properly made.
  • N
    Nicholas WagnerAug 28, 2025
    How to prevent excessive frost build-up in my Veco Compressor system?
    • K
      Kimberly MoralesAug 28, 2025
      To prevent excessive frost build-up in your Veco Compressor system, ensure that: * All drains and holes in the box are sealed. * If using a circulating fan, it's not too powerful and doesn't force cold air out of the box. * Door/lid seals are in good condition. Replace if necessary. A good seal should grip a dollar bill when closed. Apply masking tape to suspect areas after defrosting and check for frost build-up after several days to identify leaks.
  • S
    Scott GravesNov 3, 2025
    What to do if Veco Compressor is not running and there is no start attempt?
    • A
      angela99Nov 3, 2025
      If your Veco Compressor isn't starting, several factors could be at play: * **Voltage Issues**: Ensure the supply voltage at the controller terminals is at least 11.7v for a 12v system or 24.2v for a 24v system. Inspect the power supply, ground connections, and wiring. Charge the batteries if needed. * **Incorrect Polarity**: Verify the polarity is correct at the controller. * **Thermostat Problems**: Bypass the thermostat by bridging the “C” and “T” terminals. If it runs, replace the thermostat. Also, check the thermostat wiring and connections. * **Speed Board/Merlin II**: If installed, ensure the connectors are properly attached to the controller. Try removing the board and jumpering terminals C and T on the controller (note: this will run the compressor at its slowest speed). ...
  • P
    Pamela JonesNov 15, 2025
    Why is the box temperature too high when my Veco Compressor system runs?
    • W
      wwhiteNov 15, 2025
      If your Veco Compressor system is running but the box temperature is too high, consider the following: * **Thermostat**: Adjust the thermostat to a higher setting. * **Speed Setting**: Ensure the speed setting is appropriate for the evaporator and its intended use (refrigerator or freezer). * **Thermostat Type**: Verify you're using the correct thermostat type (freezer thermostat for freezers, refrigerator thermostat for normal applications with Bin and Horizontal evaporators). * **Evaporator**: If the evaporator has an even coating of frost and the system isn't cycling, it might be too small. Consider replacing it with a larger model, adding insulation to the box, or relocating the evaporator lower in the box. * **Frost Build-up**: Defrost the system to remove excessive frost, ...
  • A
    Aaron PaulNov 21, 2025
    Why is my Veco Compressor system running but the box temperature is too low?
    • J
      Jason PhillipsNov 21, 2025
      If your Veco Compressor system is running, but the box temperature is too low, check the following: * **Thermostat Setting**: Adjust the thermostat to a lower setting. * **Thermostat Type**: Ensure you are using a refrigerator thermostat (white housing) for refrigerator applications and with Bin (B) and Horizontal (H) type evaporators. * **Faulty Thermostat**: If the system runs continuously with the thermostat at its lowest setting, check the thermostat connections. If the compressor stops when you remove a connection, control the system manually from the breaker until you can replace the thermostat. * **Sensor Contact**: Make sure the mechanical thermostat sensor is in good thermal contact with the evaporator at the designated location. * **Spillover System**: If using a spill...

Summary

Chapter 1 Frigoboat Systems

Chapter 2 Air Cooled Models

Chapter 3 Water Cooled with Pump

Raw Water Pump

Details on the self-priming raw water pump and its installation requirements.

Chapter 4 Water Cooled with Keel Cooler

Keel Cooler Installation

Instructions for mounting and installing the keel cooler through the hull.

Keel Cooler Grounding and Cleaning

Chapter 5 Danfoss;Secop Electronic Controller

Voltage, Speed, and Fault Codes

Covers controller voltage, compressor speed selection, and diagnostic fault codes.

LED Alarm Indicator

Chapter 6 Evaporator Types and Installation

Evaporator Location & Airflow

Guidance on positioning evaporators for optimal airflow and temperature maintenance.

Bending & Installing Evaporators

Instructions for bending flat plates and installing evaporator units.

Thermostat Sensing Tube and Evaporator Mounting

Chapter 7 Mechanical Thermostats

Thermostat Types, Mounting, and Operation

Covers thermostat applications, installation, and how to set them.

Chapter 8 Spillover Kit Installation

Spillover Kit Mounting, Electrical, and Operation

Details on spillover kit installation, wiring, and operational settings.

Chapter 9 Quick Connect Refrigerant Fittings

Connecting Quick Connect Fittings

Step-by-step instructions for properly joining male and female refrigerant fittings.

Chapter 10 Electrical

Power Supply, Wire Size, and Protection

Guidelines for power, wire gauge, and overload protection for the system.

Controller and Thermostat Connections

How to connect power and thermostats to the electronic controller.

Fan and Pump Connections

Chapter 11 Troubleshooting Guide

Compressor Not Running

Troubleshooting steps for when the compressor fails to start or attempt a start.

Compressor Starts then Stops

System Runs, Box Temp Too High

System Runs, Box Temp Too Low

Excessive Frost Build-up

Poor Spillover System Construction

Limited Warranty Policy

Veco Frigoboat Paris 35F Specifications

General IconGeneral
BrandVeco
ModelFrigoboat Paris 35F
CategoryCompressor
LanguageEnglish