Benchtest type - Press ENTER to display the
current Benchtest type.
Use the or keys to select UK, French,
German, Swedish, Dutch, Belgium or to
Custom the bench test procedure.
Press ENTER to select the required type.
DIAGNOSTICS MENU
:Benchtest type
Benchtest type
:UK
2.7 Selection of tachograph type
Before using the Programmer, the model of tachograph
being calibrated must be selected from the Main Menu.
When the Programmer is switched on the first item displayed
on the MAIN MENU is TACHO SELECT. From elsewhere in
the MAIN MENU press the or keys until TACHO
SELECT is displayed.
Press ENTER and the TACHO TYPE menu will be displayed.
Press ENTER again and then use the or keys to select
the appropriate tachograph type (Stoneridge
VR2400/8400/8300/1400/SE5000 series, Kienzle
1324/1319/1318/ 1314/DTCO, Motometer EGK-100 and
Actia Smartach). Press ENTER to make the selection and then MENU to return to the MAIN
MENU.
2.8 Selection of Pulser type (Stoneridge VR8300/1400)
For Stoneridge VR8300 or VR1400 series tachographs, the
pulser type to be used must also be selected. This is to
ensure that any calibration factor determined is correct.
With the Programmer at the MAIN MENU and displaying
PULSER SELECT, press ENTER and PULSER TYPE will be
displayed. Use the or keys to select the appropriate
pulser type. Press ENTER to make the selection and then
MENU to return to the MAIN MENU.
Note: The 2 pulse/rev option should only be selected when the tachograph is fitted with a
Stoneridge Veeder-Root 2-pulse sender. The 8 pulse/rev option must be selected for all other
pulsers regardless of the actual number of pulses per rev from the sender.
VR2400 MAIN MENU
:TACHO SELECT
TACHO TYPE
:2400 Series
VR1400 MAIN MENU
:PULSER SELECT
PULSER TYPE
:8 Pulses/Rev

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root Stoneridge Tachograph Programmer and is the answer not in the manual?

Veeder-Root Stoneridge Tachograph Programmer Specifications

General IconGeneral
BrandVeeder-Root
ModelStoneridge Tachograph Programmer
CategoryMotherboard
LanguageEnglish