EasyManua.ls Logo

Veeder-Root TLS-350R - Page 48

Veeder-Root TLS-350R
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ISD Reports Viewing ISD Reports via RS-232 Connection
42
Assist Systems - Hose No Test Result
If the Degradation test did not run and the Gross test did not run, then an N is posted.
If there were no events received to make any conclusion about the A/L value for the hose, the A/L value is
replaced with N.
If there are some events received, enough to calculate an average, but not enough to complete a test, the No
Test result will appear with an A/L average.
Assist Systems - Hose Pass Result
When none of the above results W,F,G,D,N appear then it is a pass.
If the Degradation test did not run (no test), but the Gross test passed, the result is a PASS.
If the Gross test did not run (no test), but the Degradation test passed, the result is a PASS.
Assist Systems - Code Precedent (listed high to low)
1. G, F - Gross Failure (A/L) and Gross Stat Failure (BLKD)
2. D - Degradation Failure (A/L)
3. W - Gross Warning (A/L) and Gross Stat Warning (BLKD)
4. W - Degradation Warning (A/L)
5. PASS - Pass Gross and/or Degradation test.
6. N - No Test - Neither Gross nor Degradation test completed.
Assist Systems - Self Test Codes
ISD-W - A self-test warning condition exists. See ISD Setup.
ISD-F - A self-test warning condition persisted for 7 days and resulted in a Failure.