Vega VEGAFLEX 81 - 3.2 Principle of operation

Vega VEGAFLEX 81
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
3 Mounting - standard
VEGAFLEX 81 • Cargo tank (crude oil)
39154-EN-130626
h
d
max level
max level
x
x
1
2
Fig. 17: Mounting options
1 Flush mounting
2 Socketmounting
x Upper dead band (no measurement possible in this area)
h Socketheight
d Socketdiameter
Keep in mind that a min. distance must be maintained below the refer-
ence plane - measurement is not possible here (dead band).
The value x states the max. upper value of the measuring range as
distance to the level. This value depends on the medium.
Medium x
Water 80 mm (3.15 in)
Oil, bitumen 150 mm (5.91 in)
Solvents 150 mm (5.91 in)
If a socket is required, you can nd the optimised dimensions d and h
in the following table.
d h
DN 50 … DN 150 150 mm (5.91 in)
DN 150 … DN 200 100 mm (3.94 in)