9
3 Mounting - standard
VEGAFLEX 81 • Cargo tank (crude oil)
39154-EN-130626
h
d
max level
max level
x
x
1
2
Fig. 17: Mounting options
1 Flush mounting
2 Socketmounting
x Upper dead band (no measurement possible in this area)
h Socketheight
d Socketdiameter
Keep in mind that a min. distance must be maintained below the refer-
ence plane - measurement is not possible here (dead band).
The value x states the max. upper value of the measuring range as
distance to the level. This value depends on the medium.
Medium x
Water 80 mm (3.15 in)
Oil, bitumen 150 mm (5.91 in)
Solvents 150 mm (5.91 in)
If a socket is required, you can nd the optimised dimensions d and h
in the following table.
d h
DN 50 … DN 150 150 mm (5.91 in)
DN 150 … DN 200 100 mm (3.94 in)