3 Mounting - standard
VEGAFLEX 81 • Cargo tank (crude oil)
39154-EN-130626
3 Mounting - standard
3.1 Actuating variables
General information
1
2
34
Fig.16:VEGAFLEX81-Mounting
1 Energyeld
2 Containerframe
3 Heating coil
4 Pump
High frequency microwave pulses are guided along a steel cable or
rod.
The microwave pulses generate an energy eld with a radius of ap-
proximately 300 mm (11.81 in) around the sensor cable.
Installations within this energy eld inuence the measurement.
Process tting
If possible, avoid vessel sockets. Mount the sensor ush to the vessel
ceiling.
If this is not possible, use short sockets with small diameter.