EasyManua.ls Logo

Veikong VFD500-PV - User Manual

Veikong VFD500-PV
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operation manual
VFD500-PV/VFD500M-PV
Series
Solar Pump Inverter
Question and Answer IconNeed help?

Do you have a question about the Veikong VFD500-PV and is the answer not in the manual?

Summary

Chapter 1 Electrical cable Connection

1.1 VFD500-PV Electrical cable Connection

Details wiring for VFD500-PV models.

1.2 VFD500 M-PV Electrical cable Connection

Details wiring for VFD500M-PV models.

1.3 Electrical Specifications

Lists technical electrical specifications for the inverter.

1.4 Power degree AND Technical SPECIFICATION

Outlines power ratings and technical specifications.

Chapter 2 Motor Pump Connection

2.1 Three phase motor pump connection

Wiring diagram for three-phase motor pump connections.

2.2 Single phase motor connection (with capacitor)

Wiring for single-phase motors with capacitors.

2.3 Single phase motor wiring (without capacitor)

Wiring for single-phase motors without capacitors.

2.4 Grid and Solar DC supply compensation

Connects grid and solar DC supply simultaneously.

2.5 Control Circuit Terminal

Explains the functions of control circuit terminals.

2.6 Trial run and setup

Steps for initial startup and trial run of the inverter.

Chapter 3 Keypad display

3.1 Operation and display indicators

Explains the operation panel and indicator lights.

3.2 Display hierarchy and menu navigation

Describes the inverter's display layers and menu navigation.

3.3 Monitor display modes

Details the inverter's monitoring display modes.

3.4 Menu mode operation

Navigating through the inverter's menu options.

3.5 Error codes and handling

Lists and explains potential error codes and warnings.

Chapter 7 Service Agreement

Guarantee and warranty terms

Outlines the free-service period and warranty conditions.

Appendix A AC;DC switching scheme

A.1 Switching board solution

Explains the AC/DC switching board functionality.

A.1.3 Debugging and switching process

Steps for debugging and configuring the switching board.

Appendix B Recommended solar cell module configuration

Appendix C GPRS module and monitoring APP

Veikong VFD500-PV Specifications

General IconGeneral
CoolingForced air cooling
Rated Power5.5kW
Control ModeVector control
ProtectionOvervoltage, Short Circuit, Overheating
Protection FeaturesOverload, Overvoltage, Short Circuit, Overheating
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity5% to 95% non-condensing
Altitude≤2000m