DVM860BL - 3 - VELLEMAN
5.2 Electrical Specifications
5.2.1. DC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
600V 1V
±0.7% of rdg + 2 digits
Input Impedance : 10MΩ
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or V rms AC for the ranges 2V to 600V
Max. Input Voltage : 600V DC
5.2.2. AC Voltage
Range Resolution Accuracy
200mV 0.1mV
2V 0.001mV
20V 0.01mV
200V 0.1mV
±0.8% of rdg + 3 digits
600V 1V ±1.0% of rdg + 3 digits
Input Impedance : 10MΩ
Overload Protection : 250V DC or rms AC for the 200mV-range, 600V DC or AC rms for the ranges 2V to 600V
Frequency Range : 40 to 400Hz
Response : average response, calibration in rms of a sine wave.
Max. Input Voltage : 600V rms AC
5.2.3. DC Current
Range Resolution Accuracy
200µA 0.1µA
2000µA 1µA
20.00mA 0.01mA
200.00mA 0.1mA
±1.2% of rdg + 3 digits
2.000A 0.001A
10.00A 0.01A
±2.0% of rdg + 10 digits
Overload Protection : F 200mA/250V fuse (quick-acting) for the µA, mA ranges. The 2A and 10A range are unfused.
Max. Input Current : INPUT jack: 200mA, 10A jack: 10A.
Voltage Drop : 200µV, 20mA, 2A: 20mV, 2000µA, 200mA, 10A-range: 200mV.
5.2.4. AC Current
Range Resolution Accuracy
200µA 0.1µA
2000µA 1µA
20.00mA 0.01mA
200.00mA 0.1mA
±1.5% of rdg + 5 digits
2.000A 0.001A
10.00A 0.01A
±3.0% of rdg + 10 digits