Dafne chronothermostat, user’s manual
3s
3s
Remotely switching off (battery powered model only)
Dafne has an input for the connection to a clean contact to whom to connect for
example a telephone dialler to switch on or to switch off the chronothermostat
remotely with your own telephone.
The contact can have one of these two positions:
- open à normal operation (according to the settings)
- closed à chronothermostat in off mode
Remotely off status is displayed with the flashing symbol
on field (9) to
differentiate it from the keyboard off status (
fixed on field (9)).
Attention: remotely off status (closed contact) is more important than any
other programming, so the device will be in off status until the contact
doesn’t return to the open position.
To reactivate the regulation, returning to the operating (automatic or manual) preceding
the switching off, press the key
for about 3 seconds.