EasyManuals Logo

Venmar HF 3.0 User Manual

Venmar HF 3.0
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
6.1 MAIN SWITCH
All units are equipped with a 3-position main switch, located on the front panel.
6.2 WALL CONTROL
The included wall control is C34 (intented for HRV 2500, HEPA 3000 and HEPA 4000 units only)
or CMR control (intented for HF2.5 and HF 3.0 units only).
C34
CONTROL OR CMR CONTROL
6.3 OPERATING C34 / CMR CONTROL
6.3.1 C34 / CMR CONTROL DESCRIPTION
6.3.2 USING C34 / CMR CONTROL
• OFF: To stop the unit, slide the button on this position.
• N
ORMAL: For a day-to-day usage, slide the button on this position. The unit then will operate on normal speed.
• B
OOST: For a high speed operation, slide the button on this position. Generally used when extreme conditions occur, eg.: parties,
smokers, etc.
• R
ECIRCULATION: For a normal speed operation, without exchanging air with the outside, slide the button on this position. This mode
is recommended in high humidity days (rain, heat wave). Also, use it when the outside temperature is extremely
cold and/or the inside air is too dry. It can be used also to recirculate the heat coming from a wood stove through
out the house, or the fresh air from a cooling system.
6. CONTROLS
OFF:
U
NIT IS OFF AND
DOOR IS
UNLOCKED.
NORMAL/REMOTE:
UNIT IS OPERATING ON
NORMAL SPEED.THIS IS
THE RIGHT POSITION
WHEN A WALL CONTROL
IS USED.
BOOST:
U
NIT IS OPERATING
ON HIGH SPEED.
VC0055
VC0053
- 18 -
VC0055
FRESH AIR INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH IS ON
NORMAL OR BOOST POSITION.
FILTER MAINTENANCE INDICATOR:
FLASHES WHEN IT IS TIME TO REPLACE
PREFILTER
(OR WASH FOAM FILTER)
AND WASH CORE FILTERS.
SEE BIANNUAL MAINTENANCE IN
SECTION 7.
LIGHTS UP WHEN IT IS TIME TO
REPLACE FILTER AND PREFILTER
(OR WASH FOAM FILTER) AND CLEAN
CORE AND CORE FILTERS
.SEE ANNUAL
MAINTENANCE IN SECTION 7.
RECIRCULATION INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH IS ON
RECIRCULATION.UNIT IS OPERATING
ON NORMAL SPEED.
BOOST INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH IS ON
BOOST POSITION.UNIT IS OPERATING ON
HIGH SPEED.
NORMAL INDICATOR:
LIGHTS UP WHEN SLIDE SWITCH IS ON
NORMAL POSITION.UNIT IS OPERATING
ON NORMAL SPEED
.
RESET FILTER HOLE:
O
NCE THE MAINTENANCE DONE, RESET THE FILTER
MAINTENANCE INDICATOR BY CAREFULLY INSERTING
A SMALL ROD
(EG: PAPER CLIP) IN THE RESET FILTER
HOLE
, DURING 1 SECOND.THE FILTER MAINTENANCE
INDICATOR WILL TURN OFF
.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Venmar HF 3.0 and is the answer not in the manual?

Venmar HF 3.0 Specifications

General IconGeneral
BrandVenmar
ModelHF 3.0
CategoryAir Cleaner
LanguageEnglish

Related product manuals