Read and Save These Instructions
All Hoods Must Be Installed By A Qualied Installer
INSTALLATION INSTRUCTIONS
WALL MOUNT RANGE HOOD WITH
M600 OR M1200 BLOWER
Read All Instructions Thoroughly Before Beginning Installation
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualied person(s)
in accordance with all applicable codes and standards, including re-
rated construction. Switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally
during installation.
B. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
C. Ducted fans must always be vented to the outdoors.
D. Sufcient air is needed for proper combustion and exhausting of gases
through the ue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturers guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and local code authorities.
E. ASHRAE residential ventilation standard 62.2 limits exhaust fans (total) to
a maximum of 15 CFM per 100 square feet of occupiable space, unless a
back drafting test is performed or make-up air is provided. Consult a local
HVAC engineer for make-up air evaluation.
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK
Question and Answer IconNeed help?

Do you have a question about the Vent-a-Hood M600 and is the answer not in the manual?

Vent-a-Hood M600 Specifications

General IconGeneral
Depth22 inches
Vent Size6 inches
Width30 inches
LightsYes, Halogen
MaterialStainless steel

Summary

Installation Instructions and Safety Warnings

General Safety Precautions

Follow safety guidelines for electrical work, ducting, and ventilation to prevent fire, shock, or injury.

Electrical and Fire Safety

Ensure qualified installation, power shutoff, and use only metal ductwork to minimize fire and shock risks.

Ducting Guidelines and Best Practices

Duct Size and Material Specifications

M600 requires 6" duct (28 sq in), M1200 requires 10" duct (79 sq in); use smooth, galvanized metal duct.

Recommended Duct Routing

Keep runs short, straight, use gradual turns, and increase diameter for runs over 20 feet.

Mounting and Connection Details

Recommended Mounting Height

Mount the hood so its bottom edge is no more than 30" above the cooking surface for optimal performance.

Exhaust Outlet and Duct Connection

Install duct from outside down to the outlet; M600 uses 6" round, M1200 uses a 9" tall 10" transition.

Detailed Installation Steps

Final Assembly and Testing

Related product manuals