Installation and Wiring Instructions for the SOLO Plus Bathroom Extract Fan.
IMPORTANT:
READ THESE INSTRUCTIONS
BEFORE COMMENCING THE
INSTALLATION
DO NOT install this product in areas where the following may be present or occur:
Excessive oil or a grease laden atmosphere.
Corrosive or flammable gases, liquids, or vapours.
Ambient temperatures higher than 40°C or less than 5°C.
Possible obstructions which would hinder the access or removal of the Fan.
SAFETY AND GUIDANCE NOTES
A. All wiring to be in accordance with the current I.E.T. Regulations, or the appropriate
standards of your country and MUST be installed by a suitably qualified person.
B. The Fan should be provided with a local isolator switch capable of disconnecting all
poles, having a contact separation of at least 3mm.
C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating
label.
D. The Fan should only be used in conjunction with the appropriate Vent-Axia products.
E. It is recommended that the connection to the fan connector terminals is made with
flexible cable.
F. When the Fan is used to remove air from a room containing a fuel-burning appliance,
ensure that the air replacement is adequate for both the fan and the fuel-burning
appliance.
G. The Fan should not be used where it is liable to be subject to direct water spray for
prolonged periods of time.
H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should
be fitted. Horizontal ducts should be arranged to slope slightly downwards away from
the Fan.
I. This appliance is not intended for use by persons (Including children) with reduced
physical, sensory, or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
J. Young children should be supervised to ensure that they do not play with the appliance.
K. Fans used for tropical climates.
DESCRIPTION
As standard, the SOLO Plus is suitable for panel/wall installations, flush or surface mounting, either in a horizontal or
vertical plane. 100mm ducting (flexible or straight) can be attached using the supplied adjustable spigot, providing
rear or side exit options. Adaptors for System 25 and System 50 ducting can be used in conjunction with the
adjustable spigot. For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. An optional filter is
also available (449265). Please see our catalogue or web site (www.vent-axia.com) for more information on System
25/50 and for alternative ducting and termination options.
A. INSTALLATION
PANEL MOUNTING (Surface)
1. Cut a 105mm hole through the panel, ensuring that there is sufficient space for the product to be installed and
that the filter can be removed for maintenance.
2. Removing the grille. Firstly, remove the front cover by carefully pulling each corner of the front panel until it is
free to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The
screws will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1). Lift the inner
grille from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front
assembly and Base Housing (Fig 6).