1 Display
2 On/o switch
3 Evaporator compartment
4 Disc stack
5 Water basin
6 Fragrance compartment
7 Fragrance holder
8 UVC lamp
9 Cable compartment
10 Hygiene Disc (pre-assembled)
11 Remote Control
01 04
PUTTING INTO OPERATION
OVERVIEW
01 Unpack the appliance and set it up.
Fixed mains water connection
Notes regarding the xed mains water connection
The xed mains water connection may only be installed by qualied tech-
nicians. Disconnect the device from the power grid before connecting it
to the water supply. Shut o the water supply before connecting the water
inlet tubes of the Venta LW62 WiFi. The water quality must correspond to
the drinking water ordinance of the respective country in which the device
is operated. The connection to the domestic water supply must be carried
out according to the applicable regulations of the respective country. Also,
all devices and mechanisms that are used for the supply of the water to
the device must correspond to the applicable regulations of the respective
country.
The water supply to the device must take place via a cold water
connection that:
can withstand the operating pressure.
corresponds to hygiene regulations.
The water pressure must lie between 150 and 600 kpa.
The accompanying stainless steel tube has a length of 2 m. An exten-
sion of the stainless steel tube is not permitted. A defective stainless steel
tube may only be exchanged by a Venta original spare part (available from
Venta customer service, in specialist shops). A shut-o valve must be
installed between the stainless steel tube and the domestic water supply
connection to be able to interrupt the water supply if necessary. Make sure
that the shut-o valve is also accessible in the installed state of the device.
Attention! Make sure that the appliance is switched o and the
power plug is disconnected.