22
Time Related Function Specication
Time display HH: MM
Hour format 12hr AM / PM or 24 hr
Date display DD / MM or MM / DD
Time synchronize method Through Internet time server to synchronize the UTC
Weekday languages EN / DE / FR / ES / IT / NL / RU
Time Zone +13 ~ -12 hour
DST ON / OFF
Barometer Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Barometer unit hPa, inHg and mmHg
Measuring range 540 ~ 1100hPa (relative setting range 930 ~ 1050hPa)
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ±
0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution 1hPa / 0.01inHg / 0.1mmHg
Weather forecast
Sunny / Clear, Slightly Cloudy, Cloudy, Rainy, Rainy / Stormy
and Snowy
Display modes Current
Memory modes Historical data of past 24 hours, daily Max / Min
Alarm Pressure change alert
Indoor / Outdoor Temperature Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Temperature unit °C and °F
Display range Indoor:-40 ~ 70°C(-40 ~ 158°F), Outdoor:-40 ~ 80(-40 ~ 176°F)
Indoor Accuracy
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Outdoor Accuracy
60.1 ~ 80°C ± 0.8°C (140.2 ~ 176°F ± 1.4°F)
5.1 ~ 60°C ± 0.4°C (41.2 ~ 140°F ± 0.7°F)
-19.9 ~ 5°C ± 1°C (-3.8 ~ 41°F ± 1.8°F)
-40 ~ -20°C ± 1.5°C (-40 ~ -4°F ± 2.7°F)
Resolution °C / °F (1 decimal place)
Display modes Current
Memory modes Historical data of past 24 hours, daily Max / Min
Alarm Hi / Lo temperature alert
Indoor / Outdoor Humidity Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Humidity unit %
Display range 1 ~ 99%
Indoor Accuracy
20~39% or 71~90% RH ±8%RH @ 25°C (77°F)
40~70% RH ±5%RH @ 25°C (77°F)
Outdoor Accuracy
1 ~ 20% RH ± 6.5% RH @ 25°C (77°F)
21 ~ 80% RH ± 3.5% RH @ 25°C (77°F)
81 ~ 99% RH ± 6.5% RH @ 25°C (77°F)
Resolution 1%