EasyManua.ls Logo

VERDER VERDERAIR VA 25 - User Manual

VERDER VERDERAIR VA 25
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Repair/Parts
VERDERAIR VA 25
Air-Operated
Diaphragm Pump
859.0089
Rev. M
EN
1-inch pump with modular air valve for fluid transfer applications.
For professional use only.
See page 3 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
VA25S Stainless Steel
ti14342a
VA25A Aluminum
ti13946a
ti13844a
ti13843a
End
Flange
Center
Flange
VA25P Polypropylene
VA25C Conductive
Polypropylene
VA25F PVDF
Patents Pending

Other manuals for VERDER VERDERAIR VA 25

Questions and Answers

  • K
    Kayla LynchSep 8, 2025
    What to do if VERDER VERDERAIR VA 25 won't cycle or stops after one cycle?
    • D
      Daniel JacksonSep 8, 2025
      If your VERDER Water Pump will not cycle, or cycles once and stops, it could be due to a few reasons: * The air valve is stuck or dirty, disassemble and clean it, using filtered air. * The check valve ball is severely worn and wedged in the seat or manifold, replace the ball and seat. * The pilot valve is worn, damaged, or plugged, replace the pilot valve. * The air valve gasket is damaged, replace the gasket. * The check valve ball is wedged into the seat due to overpressurization, install a pressure relief kit. * The dispensing valve is clogged, relieve pressure and clear the valve. * The air tubing is plugged (remote air control models), clear the tube.
  • R
    Rachael CortezAug 23, 2025
    How to fix air bubbles in fluid from my VERDER VERDERAIR VA 25 Water Pump?
    • T
      taylorloriAug 23, 2025
      Air bubbles in the fluid of your VERDER Water Pump can be caused by: * A loose suction line. Tighten it. * A ruptured diaphragm. Replace it. * A loose inlet manifold, damaged seal, or damaged o-rings. Tighten manifold bolts or replace seats or o-rings. * A loose diaphragm shaft bolt. Tighten or replace it. * A damaged o-ring. Replace it.
  • L
    Lynn WellsAug 25, 2025
    What to do if VERDER VERDERAIR VA 25 will not cycle?
    • A
      April AlexanderAug 26, 2025
      If your VERDER Water Pump isn't cycling, or cycles just once and stops, here are a few potential causes: * The air valve is stuck or dirty. Disassemble and clean the air valve, using filtered air. * The check valve ball is severely worn and wedged in the seat or manifold. Replace the ball and seat. * The check valve ball is wedged into the seat due to overpressurization. Install a Pressure Relief Valve. * The dispensing valve is clogged. Relieve the pressure and clear the valve.
  • W
    woodveronicaAug 27, 2025
    Why is there fluid in the exhaust air of my VERDER VERDERAIR VA 25?
    • J
      Jordan BarnesAug 27, 2025
      If you're finding fluid in the exhaust air of your VERDER Water Pump, it could be due to: * A ruptured diaphragm. Replace it. * A loose diaphragm shaft bolt. Tighten or replace it. * A damaged o-ring. Replace it.
  • A
    Angela BarnesAug 27, 2025
    How to stop air leaks from my VERDER VERDERAIR VA 25 Water Pump?
    • F
      Frank SmithAug 27, 2025
      External air leaks in your VERDER Water Pump can often be resolved by checking these components: * Ensure the air valve cover or air valve cover screws are tight. Tighten the screws if they are loose. * Inspect the air valve gasket or air cover gasket for damage and replace if necessary. * Check that the air cover screws are tight and tighten them if they are loose.
  • S
    Sydney AbbottSep 22, 2025
    Why is there moisture in exhaust air of VERDER VERDERAIR VA 25 Water Pump?
    • M
      mariecastilloSep 22, 2025
      If there's moisture in the exhaust air of your VERDER Water Pump, it's likely due to high inlet air humidity. Using a drier air supply should resolve this.
  • S
    Stacey PattersonSep 16, 2025
    Why VERDER VERDERAIR VA 25 leaks fluid externally from joints?
    • C
      Cassandra ContrerasSep 16, 2025
      If your VERDER Water Pump leaks fluid externally from joints, it's likely due to loose manifold screws or fluid cover screws (tighten them) or worn-out manifold o-rings (replace the o-rings).
  • S
    Scott AlexanderSep 18, 2025
    Why VERDER VERDERAIR VA 25 leaks fluid externally through manifold or fluid cover?
    • R
      Ronald WatsonSep 18, 2025
      If your VERDER Water Pump leaks fluid externally through the manifold or fluid cover, it's likely due to excessive pump speed or inlet starvation. You should replace the manifold and reduce the pump speed or improve the pump feed.
  • K
    Kenneth LittleSep 7, 2025
    How to fix a VERDER VERDERAIR VA 25 Water Pump that cycles but won't prime?
    • L
      Larry LewisSep 7, 2025
      If your VERDER Water Pump cycles but will not prime, it could be due to several reasons: * The pump is running too fast, causing cavitation before prime, you should lower air inlet pressure. * The check valve ball is severely worn or wedged in the seat or manifold, you should replace the ball and seat. * The seat is severely worn, you should replace the ball and seat. * The outlet or inlet is clogged, you should unclog it. * The inlet or outlet valve is closed, you should open it. * The inlet fittings or manifolds are loose, you should tighten them. * The manifold o-rings are damaged, you should replace the o-rings.
  • B
    blackwellmarkSep 4, 2025
    What to do if VERDER VERDERAIR VA 25 Water Pump exhaust air contains fluid?
    • K
      kevin49Sep 4, 2025
      If your VERDER Water Pump exhausts air containing the fluid being pumped, it's likely due to a ruptured diaphragm (and backup), a loose diaphragm shaft bolt, or a damaged diaphragm shaft bolt o-ring. You should replace the diaphragm (and backup) or o-ring, or tighten the diaphragm shaft bolt.

Summary

Safety and Warnings

Important Safety Instructions

Critical safety guidelines for pump operation and handling.

ATEX Certifications

Details on ATEX certifications for specific pump models.

Warnings

General and specific hazard warnings for pump use, maintenance, and repair.

Pump Configuration

Pump Matrix

Guide to identifying pump components using configuration numbers.

Troubleshooting and Repair

Troubleshooting Guide

Common pump problems, their causes, and solutions.

Repair Procedures

Step-by-step instructions for pump repair and component replacement.

Torque Instructions

Specifications for torquing fasteners to ensure proper sealing and operation.

Parts and Components

Parts;Kits Quick Reference

A quick reference table for available pump parts and repair kits.

Center Section

Details on the pump's center section components and rebuild kits.

Air Valve and Data Monitoring

Information on the air valve system and monitoring capabilities.

Diaphragms

Information on diaphragm types, materials, and replacement kits.

Technical Data and Support

Technical Data

Performance data, operating parameters, and dimensions.

Customer Services and Guarantee

Information on obtaining spare parts, warranty, and liability.

VERDER VERDERAIR VA 25 Specifications

General IconGeneral
TypeAir Operated Double Diaphragm Pump
Size25 mm
Max. Solid Size3 mm
Air Inlet1/4"
Liquid Inlet/Outlet25 mm
PowerAir operated
Max. Flow Rate150 liters per minute
Flow Rate150 liters per minute
MaterialPolypropylene, Stainless Steel