VERDERAIR VA 25
Air-Operated
Diaphragm Pump
859.0089
Rev. M
EN
1-inch pump with modular air valve for fluid transfer applications.
For professional use only.
See page 3 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Stainless Steel
ti14342a
Aluminum
ti13946a
ti13844a
ti13843a
End
Flange
Center
Flange
Polypropylene
Conductive
Polypropylene
PVDF

Questions and Answers

  • S
    Samuel StephensAug 16, 2025
    What to do if VERDER Water Pump cycles but will not prime?
    • M
      Michael WernerAug 16, 2025
      If your VERDER Water Pump cycles but doesn't prime, here are several possible causes and solutions: * The pump might be running too fast, leading to cavitation. Try lowering the air inlet pressure. * The check valve ball could be severely worn or wedged. In this case, replace the ball and seat. * A severely worn seat can also cause this issue; replace the ball and seat. * Check for clogs in the outlet or inlet and unclog them if necessary. * Ensure that the inlet or outlet valve is open. * Loose inlet fittings or manifolds can also prevent priming, so tighten them. * Damaged manifold o-rings can cause this problem, replace the o-rings.
  • D
    David RodriguezAug 19, 2025
    Why VERDER VERDERAIR VA25 Water Pump operates erratically?
    • M
      Marcia DukeAug 19, 2025
      If your VERDER Water Pump is operating erratically, consider the following potential causes and solutions: * A clogged suction line could be the issue; inspect and clear it. * Sticky or leaking check valve balls might be the cause; clean or replace them. * A ruptured diaphragm could be the problem; replace it. * Check for a restricted exhaust and remove any obstructions. * Damaged or worn pilot valves can cause erratic operation; replace them. * A damaged air valve can also lead to this issue; replace it. * A damaged air valve gasket might be the cause; replace the air valve gasket. * An erratic air supply can affect pump operation; repair the air supply. * Exhaust muffler icing can cause erratic behavior; use a drier air supply.
  • N
    nathan41Aug 22, 2025
    What to do if VERDER VERDERAIR VA25 will not cycle, or cycles once and stops?
    • J
      jsellersAug 22, 2025
      If your VERDER Water Pump won't cycle or cycles once and stops, consider these possible causes: * The air valve might be stuck or dirty. Disassemble and clean the air valve, and ensure you are using filtered air. * A severely worn check valve ball wedged in the seat or manifold could be the issue. Replace the ball and seat. * A worn, damaged, or plugged pilot valve can cause this problem. Replace the pilot valve. * A damaged air valve gasket can prevent cycling; replace the gasket. * If the check valve ball is wedged into the seat due to overpressurization, install a pressure relief kit. * A clogged dispensing valve can stop the pump; relieve pressure and clear the valve. * If you have a remote air control model, a plugged air tubing can cause this issue. Clear the tube.
  • R
    Richard KhanAug 25, 2025
    How to fix air bubbles in fluid from VERDER Water Pump?
    • M
      Matthew BallAug 25, 2025
      If you notice air bubbles in the fluid being pumped by your VERDER Water Pump, here are some possible causes and solutions: * A loose suction line can introduce air. Tighten it. * A ruptured diaphragm can cause air bubbles. Replace the diaphragm. * Loose manifolds, damaged seats, or manifold o-rings can be the issue. Tighten manifold bolts or replace the seats or o-rings. * A damaged diaphragm shaft bolt o-ring can also cause air bubbles. Replace the o-ring. * Pump cavitation can lead to air bubbles. Reduce pump speed or suction lift. * A loose diaphragm shaft bolt can introduce air. Tighten it.
  • N
    natashawalkerAug 27, 2025
    Why VERDER VERDERAIR VA25 exhausts excessive air at stall?
    • S
      Shawn MasonAug 27, 2025
      If your VERDER Water Pump exhausts excessive air at stall, the following issues may be the cause: * A worn air valve cup or plate. Replace the cup and plate. * A damaged air valve gasket. Replace the gasket. * Damaged pilot valves. Replace the pilot valves. * Worn shaft seals or bearings. Replace shaft seals or bearings. * Damaged or loose air tubing (on remote air control models). Replace the tubing or secure the connection. * Remote air pressure being higher than pump air pressure (on remote air control models). Regulate the remote pilot air pressure to be equal to or less than the main air.
  • L
    Lisa BradyAug 30, 2025
    How to resolve fluid in exhaust air of VERDER Water Pump?
    • C
      Crystal KingAug 30, 2025
      If the exhaust air from your VERDER Water Pump contains fluid, consider these potential causes: * A ruptured diaphragm (and backup). Replace it. * A loose diaphragm shaft bolt. Tighten or replace it. * A damaged diaphragm shaft bolt o-ring. Replace the o-ring.
  • A
    Adriana ZunigaSep 2, 2025
    Why VERDER Water Pump cycles at stall or fails to hold pressure at stall?
    • T
      tammypittsSep 2, 2025
      If your VERDER Water Pump cycles at stall or fails to hold pressure at stall, it could be due to worn check valve balls, seats, or o-rings. Replace them.
  • A
    Amy PhillipsSep 4, 2025
    What causes moisture in exhaust air from VERDER Water Pump?
    • K
      kathleen50Sep 4, 2025
      Moisture in the exhaust air of your VERDER Water Pump is likely due to high inlet air humidity. Using a drier air supply should resolve this issue.
  • N
    Nicole BrownSep 7, 2025
    How to fix VERDER Water Pump leaking air externally?
    • R
      Rebecca HunterSep 7, 2025
      If your VERDER Water Pump is leaking air externally, check the following: * Loose air valve or fluid cover screws. Tighten them. * A damaged diaphragm. Replace the diaphragm. * A damaged air valve gasket. Replace the gasket. * If you have remote air control models, ensure that the remote air pressure is not higher than the pump air pressure. Regulate the remote pilot air pressure to be equal to or less than the main air.
  • M
    moralesjenniferSep 10, 2025
    How to stop VERDER Water Pump leaking fluid externally from joints?
    • R
      ryanpatelSep 12, 2025
      If your VERDER Water Pump is leaking fluid externally from the joints, it is likely due to: * Loose manifold screws or fluid cover screws. Tighten the manifold screws or fluid cover screws. * Worn out manifold o-rings. Replace the o-rings.