EasyManua.ls Logo

Vermont Castings UVL24MN User Manual

Vermont Castings UVL24MN
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
UVL Series
Installation and Operation
Instructions for
Vent-Free Gas Log Sets*
W A R N I N G
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
When used without fresh air, vent-free log sets may give off carbon monoxide, an odorless, poisonous gas.
Some people - pregnant women, people with heart or lung disease, anemia, or persons under the influence of
alcohol, and persons at high altitudes are more affected by carbon monoxide than others.
Early signs of carbon monoxide poisoning resemble the flu - headache, dizziness, and/or nausea. If you have these
signs, the heater may not be installed or working properly. GET FRESH AIR AT ONCE! Have the heater serviced
before using it again.
W A R N I N G
If the information in this manual is not followed exactly, a fire or explosion may result,
causing property damage, injury, or loss of life.
Models UVL18RN, UVL18MN,
UVL24RN, UVL24MN, UVL30RN,
UVL30MN (Natural Gas)
Models UVL18RP, UVL18MP, UVL24RP,
UVL24MP, UVL30RP, UVL30MP
(Propane)
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Tested and listed to ANSI Z21.11.2a-2001,
Unvented Heaters, and Z21.60-1996; CGA 2.26-M96
Decorative Gas Appliances for Installation in
Solid-Fuel Burning Fireplaces.
7412957 2/02 Rev. 5
*These logsets are not for exterior use.
ATTENTION
Installation and service must be per-
formed by a qualified agency, individual,
firm, corporation, or company, experi-
enced in the installation, repair, and
servicing of this type of gas appliance. Do
not modify, alter or tamper with any part
of this heater, control, or logs.
Do not store or use gasoline or other
flammable vapors and liquids in the vicin-
ity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbors phone. Follow the gas
suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
This appliance may be installed in an
aftermarket, permanently located, manu-
factured (mobile) home, where not prohib-
ited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
INSTALLER PLEASE NOTE:
DO NOT begin installation of this gas
logset until all instructions have been
read and understood.

Questions and Answers:

Vermont Castings UVL24MN Specifications

General IconGeneral
BrandVermont Castings
ModelUVL24MN
CategoryIndoor Fireplace
LanguageEnglish

Summary

General Information

Installation Requirements

Pressure Test Points

Details on locating and using pressure test points on the gas control valve.

Odor During Operation

Explanation of potential odors during operation and their causes.

High Elevations

Guidelines for operating the appliance at high altitudes.

Planning

Installation Precautions

Crucial safety and procedural precautions to follow before and during installation.

Fresh Air Requirements for Combustion and Ventilation

Provide for Adequate Ventilation

General requirements and methods for ensuring sufficient ventilation for the appliance.

Unusually Tight Construction

Definition and requirements for homes with unusually tight construction.

Determine If You Have a Confined or Unconfined Space

Method for calculating room volume vs. appliance BTU to determine ventilation needs.

Installation Instructions

Preparing the Fireplace

Steps for preparing the fireplace for installation, including gas line setup.

Installation to Existing Gas Line

Procedures for connecting the appliance to an existing gas supply line.

Manufactured Fireplace Preparation

Specific preparation steps for manufactured fireplaces, including gas line routing.

Masonry Fireplace Installation Preparation

Guidelines for preparing masonry fireplaces, including gas line access and sealing.

Flue Damper Preparation

Instructions for preparing the flue damper for proper operation with the appliance.

Damper Stop Installation

Details on installing a damper stop to regulate flue gas flow.

Burner Assembly Location

Guidance on centrally locating the burner unit within the fireplace firebox.

Clearances

Specifies required clearances from walls, ceilings, and mantels for safe installation.

Gas Line Connection

Instructions for connecting the gas supply line to the appliance, including LP regulator use.

Positioning the Logs

Guidance on correctly positioning the logs on the grate for proper function and safety.

Fireplace Screen

Requirements for the fireplace screen, including its role in combustion air introduction.

Remote wall switch

Instructions for installing and connecting a remote wall switch for the appliance.

Operating Instructions

The First Firing

Steps and expected behavior during the initial startup and operation of the appliance.

Flame Appearance

Visual indicators for proper pilot and main burner flame characteristics.

Lighting And Operating Instructions

Lighting Instructions

Step-by-step guide for safely lighting the pilot and main burner.

To Turn Off Gas To Heater

Procedure for safely shutting off the gas supply to the appliance.

Troubleshooting

Honeywell Valve (UVL-R series)

Diagnostic flowchart for issues with Honeywell gas valves.

SIT 630 Eurosit Valve (‘M' Series)

Common problems and corrective actions for SIT Eurosit valves.

Maintenance and Safeguards

Inspecting the Venting System

Guidance on checking the venting system for obstructions and proper function.

UVL System Maintenance

Recommendations for regular cleaning and inspection of appliance components.

Replacement Parts

Information on how to identify and order replacement parts for the appliance.

Replacement Parts List

Accessories