Why won't the spark ignitor light the pilot on my Vermont Castings 36CFDV Indoor Fireplace?
- JJaime BoltonAug 19, 2025
If the spark ignitor on your Vermont Castings Indoor Fireplace won't light the pilot after repeatedly triggering the piezo, there are several potential causes. A wire might be disconnected; open the door and check to ensure the wire is connected to the ignitor. The ignitor itself could be defective; check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the pilot assembly. There might be no gas or low gas pressure; check the remote/manual shut-off valve. Low pressure can result from bent or restricted lines, or low pressure line pressure, so consult with a plumber or gas supplier. Finally, if you're using Propane/LPG, the tank might be empty; check and refill the tank if necessary.