CFDV Series Direct Vent Gas Fireplace
Installation and Operating Instructions
Models: 36CFDV, 42CFDV
20305832 8/14 Rev. 3
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for
future reference.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the re department.
Installation and service must be performed
by a quali ed installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certi ed kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.

Table of Contents

Questions and Answers

  • B
    buchananchristineAug 19, 2025
    Why won't the spark ignitor light the pilot on my Vermont Castings 36CFDV Indoor Fireplace?
    • J
      Jaime BoltonAug 19, 2025
      If the spark ignitor on your Vermont Castings Indoor Fireplace won't light the pilot after repeatedly triggering the piezo, there are several potential causes. A wire might be disconnected; open the door and check to ensure the wire is connected to the ignitor. The ignitor itself could be defective; check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the pilot assembly. There might be no gas or low gas pressure; check the remote/manual shut-off valve. Low pressure can result from bent or restricted lines, or low pressure line pressure, so consult with a plumber or gas supplier. Finally, if you're using Propane/LPG, the tank might be empty; check and refill the tank if necessary.
  • B
    baileykristaAug 27, 2025
    What to do if my Vermont Castings 36CFDV pilot won't stay lit?
    • J
      Jamie HernandezAug 27, 2025
      If the pilot on your Vermont Castings Indoor Fireplace won't stay lit after carefully following the lighting instructions, it could be due to a defective thermocouple. Ensure the flame impinges on the thermocouple, and clean or adjust the pilot for maximum flame impingement. Also, verify that the thermocouple connection at the gas valve is fully inserted and tight. To test the thermocouple, disconnect it from the valve and use a millivolt meter to measure the output. If the reading is less than 15 mV, replace the pilot assembly. If the thermocouple produces more than 15 mV, the valve may be defective and needs replacement.
  • K
    Kevin PowellSep 3, 2025
    How to fix frequent pilot outage problem in Vermont Castings 36CFDV?
    • K
      Kurt DavisSep 3, 2025
      Frequent pilot outages in your Vermont Castings Indoor Fireplace could stem from the pilot flame being either too high or too low. This improper flame height can cause the pilot safety to drop out. To resolve this, clean and adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • J
    jane23Nov 11, 2025
    What to do if my Vermont Castings 36CFDV burner will not ignite?
    • V
      Vincent DeanNov 11, 2025
      If the pilot is burning, the valve knob and switch are in the “ON” position, but the burner on your Vermont Castings Indoor Fireplace won't ignite, there are several potential causes. First, the switch, wall switch, remote control, or wiring might be defective. Check the switch and wiring for proper connections. You can use jumper wires across the switch terminals; if the burner ignites, the switch is defective and needs replacement. Repeat this process for the remote control. Alternatively, the pilot flame may be too small and needs adjustment to be closer to the thermopile. Also, the thermopile itself might be defective or malfunctioning; ensure all wire connections are tight and the thermopile is fully inserted into the pilot assembly. A millivolt meter reading below 325 mV indicates th...

Vermont Castings 36CFDV Specifications