5832
36CFDV cover
CFDV Series Direct Vent Gas Fireplace
Installation and Operating Instructions
Models: 33CFDV(N/P)(V/I)SL, 36CFDV(N/P)(V/I)SL, 42CFDV(N/P)(V/I)SL
20306739 1115 Rev. 2
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for
future reference.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the re department.
Installation and service must be performed
by a qualied installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certied kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Un panneau vitré chaud peut
causer des brûlures.
Laissez refroidir le panneau
vitré avant d’y toucher.
Ne laisser jamais les enfants
toucher le panneau vitré.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
Une barrière visant à réduire le risque de brûlure
par le hublot chaude est fournie avec cet
appareil et doit être installé.
DANGER
CERTIFIED
S
AFETY BARRIER

Table of Contents

Questions and Answers

  • K
    kaitlin74Aug 16, 2025
    Why won't the spark ignitor light the pilot on my Vermont Castings 36CFDVNV?
    • K
      Keith MitchellAug 16, 2025
      If the spark ignitor on your Vermont Castings Indoor Fireplace won't light the pilot after repeatedly triggering the piezo, there are several potential causes. A wire might be disconnected; open the door and check to ensure the wire is connected to the ignitor. The ignitor itself could be defective; check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the pilot assembly. There might be no gas or low gas pressure; check the remote/manual shut-off valve. Low pressure can result from bent or restricted lines, or low pressure line pressure, so consult with a plumber or gas supplier. Finally, if you're using Propane/LPG, the tank might be empty; check and refill the tank if necessary.
  • B
    Brittany WareAug 20, 2025
    What to do if my Vermont Castings 36CFDVNV pilot won't stay lit?
    • R
      Renee AllenAug 20, 2025
      If the pilot on your Vermont Castings Indoor Fireplace won't stay lit after carefully following the lighting instructions, it could be due to a defective thermocouple. Ensure the flame impinges on the thermocouple, and clean or adjust the pilot for maximum flame impingement. Also, verify that the thermocouple connection at the gas valve is fully inserted and tight. To test the thermocouple, disconnect it from the valve and use a millivolt meter to measure the output. If the reading is less than 15 mV, replace the pilot assembly. If the thermocouple produces more than 15 mV, the valve may be defective and needs replacement.
  • B
    Bill BridgesAug 25, 2025
    How to fix frequent pilot outage problem in Vermont Castings Indoor Fireplace?
    • A
      Alicia LiAug 25, 2025
      Frequent pilot outages in your Vermont Castings Indoor Fireplace could stem from the pilot flame being either too high or too low. This improper flame height can cause the pilot safety to drop out. To resolve this, clean and adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • D
    David NielsenSep 8, 2025
    Why does my Vermont Castings 36CFDVNV have frequent pilot outage problem?
    • S
      Sharon SaundersSep 8, 2025
      Frequent pilot outages in your Vermont Castings Indoor Fireplace can often be attributed to the pilot flame being improperly adjusted—either too high or too low. This can cause the pilot safety mechanism to shut off. To resolve this, clean and adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • K
    Kimberly MooreNov 12, 2025
    What to do if my Vermont Castings Indoor Fireplace burner will not ignite?
    • K
      Katelyn BaileyNov 12, 2025
      If the pilot is burning, the valve knob and switch are in the “ON” position, but the burner on your Vermont Castings Indoor Fireplace won't ignite, there are several potential causes. First, the switch, wall switch, remote control, or wiring might be defective. Check the switch and wiring for proper connections. You can use jumper wires across the switch terminals; if the burner ignites, the switch is defective and needs replacement. Repeat this process for the remote control. Alternatively, the pilot flame may be too small and needs adjustment to be closer to the thermopile. Also, the thermopile itself might be defective or malfunctioning; ensure all wire connections are tight and the thermopile is fully inserted into the pilot assembly. A millivolt meter reading below 325 mV indicates th...
  • J
    Jason ThomasNov 27, 2025
    What to do if Vermont Castings Indoor Fireplace burner will not ignite?
    • V
      Valerie BennettNov 27, 2025
      If your Vermont Castings Indoor Fireplace burner won't ignite even with the pilot burning, valve knob on 'ON,' and the switch also on 'ON,' several factors could be at play. First, check the switch and wiring for secure connections. You can test the switch by placing jumper wires across its terminals; if the burner ignites, the switch is faulty and needs replacement. Repeat this process for the remote control. If the burner ignites when a jumper wire is placed across the wires at the gas valves (terminals marked TH and TP/TH), the wires are likely faulty or have poor connections and should be replaced. Also, the pilot flame might be too small and not close enough to the thermopile, so adjust the pilot flame. A defective or malfunctioning thermopile can also be the reason. Check the thermop...
  • N
    nancy50Dec 1, 2025
    How to fix Vermont Castings 36CFDVNV spark ignitor that will not light pilot?
    • C
      Caroline BakerDec 1, 2025
      If the spark ignitor on your Vermont Castings Indoor Fireplace won't light the pilot after repeatedly triggering the piezo, there are several potential causes. First, ensure the wire is properly connected to the ignitor by opening the door and checking the connection. If the wire is connected, the ignitor itself may be defective. Check for a spark at the electrode and pilot; if there's no spark and the electrode wire is properly connected, replace the pilot assembly. Another possible cause is a lack of gas or low gas pressure. Check the remote/manual shut-off valve from the fireplace. Low pressure can result from bent or restricted lines, or generally low line pressure, in which case you should consult with a plumber or gas supplier. Finally, if you're using propane/LPG, check the tank to ...

Vermont Castings 36CFDVNV Specifications

General IconGeneral
Vent TypeDirect Vent
WeightApproximately 300 lbs
Glass TypeCeramic Glass
WarrantyLimited Lifetime Warranty
TypeFireplace
Fuel TypeNatural Gas
Heating CapacityUp to 1, 800 sq ft
Ignition TypeElectronic
EfficiencyUp to 70%
Log MaterialCeramic Fiber