Chapter 1: Introduction

1.4. Main Components

Details the key components of the Liebert CRV4 indoor unit.

1.4.1. EC Compressor

Details the EC compressor features: low noise, vibration, high reliability.

Chapter 2: Installation

2.4. Refrigerant Charging Requirement

Explains the need for per-specified quality refrigerant (R410A) for optimal efficiency.

2.5. Transportation, Unpacking and Inspection

Procedures for safely transporting, unpacking, and inspecting the unit.

Chapter 3: Mechanical Installation

3.1. System Arrangement during Installation

Details system arrangement and layout considerations for installation.

3.1.3. Mechanical Parameters

Displays mechanical parameters of the indoor unit including dimensions and weight.

3.2. Installation of the Indoor Unit

Step-by-step guide for installing the indoor unit, including leveling.

3.2.1. Leveling the Cabinet

Step-by-step illustration for leveling the cabinet using leveling feet.

3.2.2. Removing the Leveling Feet and Fastening

Instructions for removing leveling feet and fixing the cabinet.

3.3. Unit Piping Installation

Outlines the four types of piping to be joined and general piping considerations.

3.3.4. Connection of the Copper Piping between the Indoor and Outdoor Units

Guides connecting indoor and outdoor units via brazed copper piping, mentioning dimensions.

3.4. Charging Refrigerant and Adding Lubricant Oil

Details procedures for charging refrigerant and adding lubricant oil.

3.4.1. Charging Refrigerant

Details standard refrigerant charge amounts for outdoor and indoor units.

3.4.2. Adding Lubricant Oil

Provides guidance on adding lubricant oil, types, and amounts based on pipe OD.

Chapter 4: Electrical Installation

4.2. Liebert CRV4 Cable Connection of Indoor Unit

Guides on connecting cables for the Liebert CRV4 indoor unit.

4.2.2. Connecting the Power Cable of the Indoor unit

Details connecting supply terminals L1-L3, N, PE to their counterparts.

Chapter 5: Start-up Commissioning

5.2. Power-On Commissioning

Procedures for powering on and commissioning the system.

5.2.1. Preparation Before Commissioning

Mechanical and electrical preparation steps before powering on the unit.

5.2.2. Commissioning Procedures

Step-by-step procedures for vacuuming, charging refrigerant, and dynamic charging.

Chapter 6: Micro-Controller (Color Screen)

6.3. Control Screen

Details the interface screens for controlling the unit.

6.5. Alarm Information

How to access Alarm Information, including alarm status and history.

Chapter 7: Micro-Controller (Text-screen)

7.5. Control Screen

Describes the control screen interface and its displays.

7.6.3. Alarm Information

Accessing Alarm Info to view active and history alarm information.

Chapter 8: System Operation and Maintenance

8.9. Refrigerating System Maintenance

Maintenance instructions for the refrigerating system components.

Chapter 9: Troubleshooting

9.3. Troubleshooting of Compressor and Cooling System

Troubleshooting steps for compressor not starting or stopping, and other cooling system issues.