Installation precautions
NOTE: For installation personnel to read
Must be grounded. Otherwise, when there is a malfunction or
leakage, electric shock may occur.
During installation, maintenance, and upkeep, the power supply
must be disconnected. Otherwise, it may cause electric shock.
Installation must be carried out by professionals or trained
personnel with equivalent professional knowledge and
skills in accordance with national wiring regulations.
Otherwise, it may cause leakage, electric shock, and fire
due to incorrect wiring, twisted wiring, and wire clamping.
The installation of the product should ensure that people in the
bathtub or shower area cannot reach the switches and other
controllers.Otherwise, it may cause electric shock
It is necessary to prevent gas from flowing back into the room
from open airways or other open flame equipment. Otherwise,
it may cause a fire
When installing, a "full pole power switch" with a contact
distance of no less than 3mm must be installed in the power
supply line to connect or disconnect the main power supply. Its
rated load capacity should not be less than 250V~15A and
should be installed outside the bathroom for easy operation.
Otherwise, it may cause a short circuit and lead to a fire.
Ensure that the power cord is installed in place. Otherwise, it
may cause a fire.