- 9 -
number shows the setted level of hardness. For example, if the displayer
shows “02” it means the current setting level is 2. The stiffness will
increase one level each time that the “UP” or “DOWN key is pushed. It
circulate from “01” to “10”
( 01(soft)-02(hard)-03(harder)-------10(hardest)-01(soft))
bset parameters
Machine in “standby”mode, press “UP” and “DOWN” at the same time and
hold for 5 seconds,the SET” window displays “P1” icon(Periodic
Restarting Time Seeting), Press” ”, the window will display “05”(The
variable range is from “5~15” minutes, press”UP” and “DOW” can change
the setting volume)
Continue pressing key for two times, every time operation can change
the icon display on the window. And when each icon appears,by pressing
key for one time to change the setting you want.(Volume can be
changed by pressing “UP” and “DOWN”)
Icon
Implication
Variable Range
P1
Periodic Restarting Time Seting
Range5~15 minutes
P2
Stop Delay of Beater Motor
Range:5~15 seconds
C1
Air Pump Working Time Seting
Range:1~30 seconds
C2
Air Pump Off-Working Time Seting
Range:1~30 seconds
P8
Pre-Cooling temperature of the
hopper
Range:1~15
P9
Pre-Cooling temperature of the
cylinder
Range:1~15
Press , the machine will enter circulatory volume setting. Without any
operation in ten seconds, setting volumes will be automatically saved and
back to the standby mode.