Installation steps:
Install three-way ball valve > PE pipe > 1/4” quick connector > tap adapter
B
Step 1: Drilling: Within 70mm of the edge of the sink, drill a through hole
(diameter 142mm) on the counter surface with an electric drill. Note:
Marble counter tops need to use an φ14mm glass hole opener.
Step 2: Fix the 2-2 valve: Insert the 2-2 valve into the hole and fix it on the
counter with a hex nut.