- 31 -
water, as the water could be contaminated by these types of containers.
Don't disassemble the machine & components. Don't block, fold or break
the outlet tube. When the machine is working, for the purpose of expelling
water freely, don't keep the Drain water outlet tube in a high place. And the
Drain water tube should be no more than 60cm in length.
Every morning before collecting alkaline water from the ionizer, allow the
water to run for 10~30 seconds to ush out the water in the machine and
filters. And the end of the day, it is suggested to flush for 10-15 seconds in
the Purified water” level and Sanitizing water level to prevent scaling.
The ionized alkaline & acidic water should be used as soon as possible
within 24 hours.
Don't take medicine with alkaline water. Please use purified water.
Don't drink acidic water.
Please disconnect the power plug when not using the machine for long
period.
Troubleshooting
Issue 1: The power supply light is not on or LCD screen does not display.
Solution: please check electricity power supply is connected properly and
re-plugin the cord.
Issue 2: Touch control panel does not function or respond (but the
machine can still work normally).
Solution: Please unplug the power cord and wait a minute, then plugin the
power cord. After the power is re- applied, the unit should return to normal
operation. Note: Do not share the power supply with a large power
appliance. Do not locate the ionizer near electromagnetic radiation
appliances, i.e. microwave ovens.
Issue 3: Background light on LCD is not on and the LCD is dark, when
water passes through.
Solution: The tap water pressure is LOW ( Less than 0 . 8L/ minute water
output), please increase the water pressure and check if the filter blocked