Technical Support and E-Warranty Certificate www.vevor.com/support
SEWAGE PUMP
INSTALLATION INSTRUCTIONS
MODEL: FLO500
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only represents an
estimate of savings you might benefit from buying certain tools with us compared to the major
top brands and doses not necessarily mean to cover all categories of tools offered by us. You
are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.

Questions and Answers

  • J
    Jermaine WhitakerAug 7, 2025
    What to do if my VEVOR FLO500 motor is not switched on?
    • K
      keithlisaAug 7, 2025
      If the VEVOR Water Pump motor isn't starting, first ensure the power supply is switched on. If it is, and the pump still doesn't start, the plug may be defective and require repair. Also, the issue might stem from a motor or sensor malfunction; in this case, remove the lid, flush it clean, and dry the sensor thoroughly with a hair dryer.
  • R
    Russell LyonsAug 15, 2025
    Why does my VEVOR Water Pump run non-stop or for a long time?
    • R
      raybrianAug 15, 2025
      If the VEVOR Water Pump engine runs non-stop or for extended periods, first, check the drain installation. Ensure that the height or length of the drain isn't excessive and that there aren't too many bends. Also, the pump might be blocked. If so, turn off the power, disassemble the pump, and remove any blockages.
  • E
    Emily DavidsonAug 22, 2025
    What to do if my VEVOR FLO500 Water Pump occasionally starts to work?
    • L
      lwallaceAug 22, 2025
      If your VEVOR Water Pump only starts occasionally, it may be due to leaking pipelines. Check the installation in front of the appliance. Alternatively, the check valve could be leaking. In this case, try cleaning or replacing the check valve.
  • G
    Gina RobinsonAug 30, 2025
    Why is my VEVOR FLO500 Water Pump motor rattling with a noise?
    • J
      James ScottAug 30, 2025
      If the VEVOR Water Pump motor is rattling and making noise, there might be a foreign object inside. Remove the lid, clean the area, and remove any object. If the noise persists, the condenser may be broken or there may be motor trouble, it is best to contact a qualified specialist or the supplier.

Summary

Accessories

Check Valve with Plastic Elbow

Item A-B: check valve with plastic elbow.

Hose Clamps

Items C, G, H: Various sizes of hose clamps (32-50mm, 90-110mm, 110-120mm).

Toilet Connection Rubber Ring

Item D: Rubber ring for connecting toilet and pump.

Plastic Hose

Item E: Plastic hose accessory.

Activated Carbon

Item F: Activated Carbon accessory.

Pump Lid and Plug

Items J (Lid) and K (Plug, mounted on pump).

Specifications

Input Power and Voltage

500W input power rating and 220-240V, 50HZ input voltage.

Flow Rate and Lift Capabilities

110L/MIN flow rate and 8M vertical, 80M horizontal lift.

Operating Parameters

Max temperature 90°C, noise level 45 dBA, IPX4 degree of protection.

How the Unit Functions

Installation Guidelines

Electrical Installation

Unit must be installed to current electrical regulations by a registered electrician.

Plumbing Connections

Use radius bends, avoid 90-degree elbows for pipe runs.

Horizontal Outlet Inclination

Water pipe must have a 1% inclination for horizontal discharge.

Inlet Configuration

Unit accepts one input (toilet, shower, sink) with blanking covers.

Warnings

Electrical Installation Safety

Connection by qualified technician, follow rules, replace damaged power cords.

Thermal Protection and Water Supply

Appliance switches off when overheating; close water supply during absence.

Personal Security Risks

Failure to follow indications may cause personal security risks.

Prohibited Items and Wrong Use

Use only for human excrement+toilet paper; improper use voids warranty.

Troubleshooting

Appliance Starts Intermittently

Check pipelines and check valve for leaks.

Slow Water Drainage

Check for blocked aerator in the lid.

Continuous or Long Motor Operation

Check drain height, length, bends, or pump blockages.

Motor Not Starting

Verify power supply and check plug for defects.

Motor Noise

Inspect motor for foreign objects.

Motor Buzzing Without Rotation

Check condensator or inspect motor for foreign objects.

VEVOR FLO500 Specifications

General IconGeneral
BrandVEVOR
ModelFLO500
CategoryWater Pump
LanguageEnglish

Related product manuals