Model | T-BERD 6000A V2 |
---|---|
Category | Test Equipment |
Mainframe Slots | 2 |
Display | Touchscreen |
Battery Life | Up to 8 hours |
Connectivity | USB, Ethernet, Wi-Fi |
Optical Return Loss (ORL) Measurement Range | 0 dB to 60 dB |
Length Measurement Accuracy | ±1 m |
Operating Temperature Range | -10 °C to +50 °C |
Measurement Types | Optical Return Loss (ORL) |
Optical Interfaces | FC, SC, LC |
Optical Power Measurement Accuracy | ±0.2 dB |
ORL Measurement Accuracy | ±1 dB |
Insertion Loss Measurement Range | 0 dB to 50 dB |
Storage Temperature Range | -20°C to +60°C |
Supported Protocols | Ethernet |
Explains optical time domain reflectometry, signal detection, and information yielded by the measurement.
Steps to activate the OTDR function, including selecting Smart Test or Expert OTDR.
Details on configuring the unit for Smart Test and Expert OTDR, including parameters.
Steps for launching OTDR measurements, including Real Time mode and Smart Test.
Instructions on saving measurement results and generating reports.
Guides on selecting and configuring the Reduced Dead Zone (RDZ) function and its parameters.
Steps for executing the RDZ measurement after configuration.
Details on activating and configuring power meter measurement and alarm parameters.
Procedure for performing insertion loss measurements using light source and power meter.
Details on accessing and configuring OEO parameters for bi-directional measurements.
Step-by-step guide for performing bi-directional measurements using Process, Curve, and Summary pages.
Steps to activate the FiberComplete function using the HOME page and relevant icons.
Explains the importance and methods for referencing leads or patch cords for accurate measurements.
Details on configuring acquisition parameters, IL/ORL measurement, and other settings.
Details analysis settings like Channel Detection, Signal Threshold, Min. Channel spacing, and OSNR.
Steps for activating the PMD function and performing self-calibration.
Guide for installation and performing in-band PMD-OSNR measurements using the I-PMD module.
Details on loading configuration files and setting up the OSA instrument.
Guides for setting up the OSA, including modes like WDM/OSNR, DFB, and I-OSNR.
Covers acquisition parameters such as Sweep, Sweep Range, Averaging, and Resolution.
Guide to making AP measurements after reference setup.
Details on configuring CD tests, including approximation formulas and manual mode.
Steps for performing CD measurements after reference setup.