1. CH 1/2 Gain control
This control is used to match the input signal of the source to the amplier for channels 1 and 2. See
the setup section for more details.
2. CH 1/2 High Pass Filter (HPF) control
This control is used to set the crossover frequency for channels 1 and 2 when HPF is
selected. The frequency is adjustable between 40Hz and 600Hz or 400Hz and 6000Hz depending on
the position of the multiplier switch.
3. CH 1/2 High Pass Filter (HPF) frequency multiplier switch
This switch is used to select the frequency multiplier for the high pass lter for channels 1 and 2.
x 1 and x10 settings are selectable.
4. CH 1/2 High Pass Filter (HPF) select switch
This switch is used to turn the HPF on or off for channels 1 and 2.
5. CH 1/2 Low Pass Filter (LPF) control
This control is used to set the crossover frequency for channels 1 and 2 when LPF is
selected. The frequency is adjustable between 40Hz and 600Hz or 400Hz and 6000Hz depending on
the position of the multiplier switch.
6. CH 1/2 Low Pass Filter (LPF) frequency multiplier switch
This switch is used to select the frequency multiplier for the low pass lter for channels 1 and 2.
x 1 and x10 settings are selectable.
7. CH 1/2 Low Pass Filter (LPF) select switch
This switch is used to turn the LPF on or off for channels 1 and 2.
1 2 3 4 5 6 7 8
11 12 13 14 15
9
15 16 17 18 19 20 21 22 23
12
CVEN Channel 6 Terminals And Connections