9 | 028-0228-06 November 2015
Temperature vs. resistance chart for 10 Kohm NTC thermistor
ºC
ºF
Kohm
ºC
ºF
Kohm
ºC
ºF
Kohm
ºC
ºF
Kohm
ºC
ºF
Kohm
-40
-40
324.3197
-20
-4
94.5149
0
32
32.1910
20
68
12.4601
40
104
5.3467
-39
-38
303.6427
-19
-2
89.2521
1
34
30.6120
21
70
11.9177
41
106
5.1373
-38
-36
284.4189
-18
0
84.3147
2
36
29.1197
22
72
11.4018
42
108
4.9373
-37
-35
266.5373
-17
1
79.6808
3
37
27.7088
23
73
10.9112
43
109
4.7460
-36
-33
249.8958
-16
3
75.3299
4
39
26.3744
24
75
10.4443
44
111
4.5631
-35
-31
234.4009
-15
5
71.2430
5
41
25.1119
25
77
10.0000
45
113
4.3881
-34
-29
219.9666
-14
7
67.4028
6
43
23.9172
26
79
9.5754
46
115
4.2208
-33
-27
206.5140
-13
9
63.7928
7
45
22.7861
27
81
9.1711
47
117
4.0607
-32
-26
193.9703
-12
10
60.3980
8
46
21.7151
28
82
8.7860
48
118
3.9074
-31
-24
182.2686
-11
12
57.2044
9
48
20.7004
29
84
8.4190
49
120
3.7607
-30
-22
171.3474
-10
14
54.1988
10
50
19.7390
30
86
8.0694
50
122
3.6202
-29
-20
161.1499
-9
16
51.3692
11
52
18.8277
31
88
7.7360
51
124
3.4857
-28
-18
151.6239
-8
18
48.7042
12
54
17.9636
32
90
7.4182
52
126
3.3568
-27
-17
142.7211
-7
19
46.1933
13
55
17.1440
33
91
7.1150
53
127
3.2333
-26
-15
134.3971
-6
21
43.8268
14
57
16.3665
34
93
6.8259
54
129
3.1150
-25
-13
126.6109
-5
23
41.5956
15
59
15.6286
35
95
6.5499
55
131
3.0016
-24
-11
119.3244
-4
25
39.4921
16
61
14.9280
36
97
6.2866
56
133
2.8928
-23
-9
112.5028
-3
27
37.5056
17
63
14.2629
37
99
6.0351
57
135
2.7886
-22
-8
106.1135
-2
28
35.6316
18
64
13.6310
38
100
5.7950
58
136
2.6886
-21
-6
100.1268
-1
30
33.8622
19
66
13.0307
39
102
5.5657
59
138
2.5926
CONFIGURING AND STATUS DISPLAY INSTRUCTIONS
Status display
The Room Controller features a two-line, eight-character display. There is a low level
backlight level that is always active and can only be seen at night.
When left unattended, the Room Controller has an auto scrolling display that shows the
actual status of the system.
Each item is scrolled one by one with the back lighting in low level mode. Pressing any key
will cause the back light to come on to high level.
Manual scroll of each menu item is achieved by pressing the Yes (scroll) key repetitively.
The last item viewed will be shown on the display for 30 seconds before returning to
automatic scrolling. Temperature is automatically updated when scrolling is held.