61
Automatic On / Off NOT PROGRAMMED
press the key for 2 seconds, the buzzer will beep,
the display will light up to indicate the release of the
EPROM for about 1 second.
The control unit will start up an auto diagnosis cycle
to check the functions, all the selection keys will light
up.Once the check is completed the display will read:
with the day and time. When 110°C has been reached,
the heating message will disappear and will be replaced
by the words:
NOTE
On completion of the check up all the selection keys
are activated.
WARNING
In case the auto diagnosis indicates error or malfunc-
tion, call an assistance centre; the operator MUST NOT
intervene.
press the
key for 2 seconds; the machine will turn
off and the display will read:
Automatic On / Off PROGRAMMED
The machine will SWITCH ON at the first programmed
switch-on time (see the section entitled
at the paragraph ).
The control unit will perform an auto diagnosis of all func-
tions and all of the selection keys will light up.
Once the diagnosis is complete, the display will read as
follows:
with the date and time. Once the temperature of 110°C has
been the word “Heating” will disappear to be replaced by:
NOTE
Once the auto diagnosis has been completed all the
keys are activated.
WARNING
In case the auto diagnosis indicates error or malfunc-
tion, call the assistance centre; the operator MUST NOT
intervene.