Do you have a question about the Victron energy BlueSolar MPPT 100/30 and is the answer not in the manual?
Model | BlueSolar MPPT 100/30 |
---|---|
Category | Controller |
Maximum PV Power (12V) | 440W |
Maximum PV Power (24V) | 880W |
Maximum PV Open Circuit Voltage | 100 V |
Maximum Charge Current | 30 A |
Efficiency | 98% |
Communication Port | VE.Direct |
Communication | VE.Direct |
Battery Voltage | 12V/24V Auto Select |
Operating Temperature | -30°C to +60°C |
Self Consumption | 10mA |
Protection | PV reverse polarity protection, Output short circuit protection, Over temperature protection |
Temperature Compensation | -16mV/°C (12V), -32mV/°C (24V) |
Covers PV voltage up to 100V and ultra-fast MPPT for improved energy harvest.
Details advanced MPP detection for shading and outstanding conversion efficiency (>98%).
Explains extensive electronic protection features and internal/external temperature sensors.
Controller automatically adjusts to 12V or 24V system, only once.
Fully programmable charge algorithm with eight preprogrammed options selectable via rotary switch.
Details the three-step charging process: Bulk, Absorption, and Float stages.
Solar chargers are controlled remotely via a VE.Direct non-inverting remote on-off cable.
Configure with VictronConnect app (iOS/Android/macOS/Windows). Monitor with MPPT Control or GX Product range.
Read manual carefully, use for designated application only, install in heatproof environment.
Ensure ventilation, avoid wet/explosive environments, use insulated tools, and follow battery instructions.
Mount in heatproof area, ensure ventilation, protect modules from light, use insulated tools.
Mount vertically on non-flammable substrate with clearance. Mount close to battery, avoid direct overhead placement.
Discusses battery, chassis grounding, NEC GFPD requirements, and PV array grounding.
Details PV voltage requirements (Vbat+5V to start, Vbat+1V thereafter) and max open circuit voltage (100V).
Sequence: connect battery first, then solar array. Torque specification provided.
Presents 8 preprogrammed charge algorithms for various battery types with voltage and current settings.
Explains LED states for regular operation and fault situations, including blinking patterns.
Details charging cycle start, lead-acid absorption time calculation based on battery voltage.
Absorption ends when battery current drops below tail current (default 2A) or absorption voltage is reached.
Covers pausing absorption, restarting process, battery state before charging, and tail current determination.
Specifies default absorption voltage, time, and float setting for LiFePO4 batteries.
Default OFF. Configurable via VictronConnect app. Details current limits and duration for equalization.
Addresses issues like reversed connections, bad connections, or high cable losses with solutions.
Covers battery not fully charged or overcharged due to temperature differences or incorrect settings.
Compares MPPT 100/30 and MPPT 100/50 models across key electrical and physical parameters.
Details enclosure specifications and relevant safety standards for the controllers.