Why is my Victron energy BlueSolar MPPT 100/15 Controller not fully charging the battery?
C
carpenterrileyAug 14, 2025
If your Victron Energy Controller is not fully charging the battery, several factors could be at play. A poor battery connection might be the cause, so check the connection. High cable losses can also prevent a full charge; consider using cables with a larger cross-section. Additionally, a significant temperature difference between the charger and battery could be the issue; ensure the ambient conditions are similar for both. Finally, for a 24V system, make sure the correct system voltage (24V instead of 12V) is selected by the charge controller; disconnect the PV and battery, ensuring the battery voltage is above 19V, then reconnect properly.
B
Bruce ValentineAug 18, 2025
Why is my Victron energy BlueSolar MPPT 100/15 overcharging the battery?
R
reedsamuelAug 18, 2025
If your Victron Energy Controller is overcharging the battery, it could be due to a defective battery cell, in which case you should replace the battery. Another cause might be a large ambient temperature difference between the charger and the battery. To resolve this, make sure that ambient conditions are equal for charger and battery.
V
vanessa10Aug 21, 2025
Why Victron energy BlueSolar MPPT 100/15 charger does not function?
M
mcgeemarcAug 21, 2025
The Victron Energy Controller charger might not be functioning due to a reversed PV connection. In this case, connect the PV correctly. Another cause may be that no fuse is inserted; make sure to insert a 20A fuse.
A
Anthony RussellAug 25, 2025
What to do if the Victron energy BlueSolar MPPT 100/15 battery is not fully charged?
P
Patrick PhamAug 26, 2025
If the Victron Energy Controller battery isn't fully charged, check the battery connection, as a bad connection can be the cause. High cable losses can also prevent a full charge, so use cables with a larger cross-section. Ensure that ambient conditions are equal for charger and battery because a large ambient temperature difference between charger and battery can affect charging. Finally, if you have a 24V system, make sure that the charge controller is set to the required system voltage (24V instead of 12V).
E
evansjoelAug 28, 2025
What to do if the Victron Energy Controller battery is being overcharged?
A
angela88Aug 28, 2025
If the Victron Energy Controller battery is being overcharged, it could be due to a defect in one of the battery cells; if this is the case, replace the battery. Another possible cause is a large ambient temperature difference between charger and battery. To solve this, make sure that ambient conditions are equal for charger and battery.
B
Blake NunezAug 31, 2025
What to do if the load output on my Victron Energy Controller does not become active?
K
Kathryn HolmesAug 31, 2025
If the load output on your Victron Energy Controller doesn't activate, it could be due to several reasons. First, ensure that the output current doesn't exceed the 15A limit. Another potential cause is using a DC load with a capacitive load, such as an inverter; try disconnecting the DC load during the start-up of the capacitive load or disconnect the AC load from the inverter, or connect the inverter as explained in section 3.6. Finally, check for any short-circuits in the load connection.
B
blakemillerSep 3, 2025
What to do if my Victron energy BlueSolar MPPT 100/15 Controller's fuse is blown?
M
Megan ArnoldSep 4, 2025
If the fuse in your Victron Energy Controller blows, it's likely due to a reversed battery connection. To resolve this, first, correctly connect the battery. After correcting the connection, replace the fuse.
K
Karina CurrySep 7, 2025
What causes a blown fuse in Victron energy BlueSolar MPPT 100/15 Controller?
W
William Rodriguez IISep 7, 2025
A blown fuse in the Victron Energy Controller is often caused by a reversed battery connection. To solve this, connect the battery correctly and replace the fuse.
M
Mallory RaySep 10, 2025
How to fix Victron Energy Controller load output not becoming active?
M
Mr. Patrick McgeeSep 12, 2025
If the load output on your Victron Energy Controller isn't activating, it might be due to exceeding the maximum current limit. Ensure the output current doesn't exceed 15A. Another reason might be using a DC load in combination with a capacitive load (like an inverter). Disconnect the DC load during the start-up of the capacitive load. Check the load connection for a short-circuit.