EasyManua.ls Logo

Vicway VT PRO - Maintenance

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 17 -
Maintenance
1. No particular maintenance is required for the logic circuit board.
Check the door at least twice a year if it is properly balanced, and all working parts are in
good working condition or not.
Check the reversing sensitivity at least twice a year, and adjust if it is necessary.
Make sure that the safety devices are working effectively (photo beams, etc.)
2. Light bulb replacing:
Notice: Make sure the power supply has been cut off before replacing the light bulb. And
ensure the voltage of the new light bulb is in accordance with the local voltage and the
power is within 25 Watt.
Demount the screws on the lamp cover. Take the lamp cover away then twist off the old
light bulbs anti-clockwise. Fix the new lamp bulb and lamp cover.
Notice: A rude operating door can affect the life of the automatic opener due to incorrect
loads, and will void the warranty.
Technical specifications
VT 1000E
VT PRO
Power Input
245W
260W
Input Voltage
220V ~ 240V AC, 50Hz
Light time
3 minutes
Working temperature
-20°C ~ 40°C
Relative Humidity
<90%
Max force
1000N
1200N
Rated load
400N
450N
Reception frequency
433.92 MHz or according to customer’s requirement
Sensitivity
>1 V for correct receiver signal
Decoding
Rolling code
Transmitter power
27A 12V Battery
Lamp
LED, 24V DC