2-4 Electrical Safety Guidelines Rev AA
Videojet 1710 Operator Manual
PERSONAL INJURY. Always ground conductive equipment to an
earthing electrode or to the building grounding system with
approved cables as per NEC standards in order to drain all potential
static discharge. For example, a metal service tray to earth ground.
PERSONAL INJURY. A resistance reading from the grounded
service tray to the equipment chassis or mounting bracket should be
0 to less than 1 ohm. A resistance check should be made using a safe
and reliable ohmmeter and should be done on a frequent basis.
PERSONAL INJURY. The PCBs contain static sensitive devices. A
suitably grounded, antistatic wrist strap must be worn when
working on or handling PCBs.
PERSONAL INJURY. Always prevent static discharge from
occurring. Use proper Grounding and Bonding methods. Only use
Videojet approved metallic service trays and ground cables.
PERSONAL INJURY. Always bond conductive equipment together
with approved cables to maintain them at the same potential and
minimize static discharge. For example, printhead to metal service
tray.