NOTICE!
Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks
may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully
lined and that there must be no hollow spaces.
3.2.3 Sealing the drain
NOTICE!
Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks
may occur when pressure is applied.
Check the proper completion of the subsequent work.
Screed and floor tiles must be laid at an incline of 1–2 % in
the direction of the drain.
Requirements:
n The flange is free of heavy soil.
n The complete surface of the flange is lined with material and undam‐
aged.
Remove protective foil.
Bonded sealing
Handling