Explains safety symbols (Danger, Note) and their meanings for hazard communication.
Defines the target audience as qualified personnel and lists applicable safety regulations.
Critical actions for gas leaks, focusing on immediate safety measures and hazard prevention.
Outlines procedures for handling flue gas hazards to prevent poisoning and ensure ventilation.
Covers safe practices during system operation, isolation, electrical safety, and component repair.
Addresses risks from static discharge and the importance of using genuine spare parts.
Overview of the Vitogate 200 EIB gateway and its function with Vitotronic control units.
Lists compatible Vitotronic control units for KNX/EIB system communication.
Details system functions like state transfer and parameter setting via the EIB system.
Guidance on mounting the device onto standard rails in control panels or distribution boards.
Explains LON BUS topology, cable types, and connection via RJ45 plugs.
Covers power connection, earthing, fuse protection, and compliance with electrical standards.
Specifies criteria for main isolators based on DIN VDE standards for combustion equipment.
Details system behavior and data transfer when switched off by the main isolator.
Describes the Vitogate 200's operation when the heating system is powered off by the isolator.
Identifies and explains the functions of indicators, buttons, and displays on the Vitogate 200.
Instructions for integrating the LON module and managing subscriber lists and checks.
Guides users on downloading and importing the EIB product database for ETS configuration.
Details data points, their mapping to communication objects, and flag settings for EIB.
Provides guidance on configuring parameters within the ETS software for the EIB system.
Confirms that all saved datapoints are retained after power interruptions.
Describes automatic scanning and updating of communication objects after power restoration.
Details fault codes and error messages resulting from connection interruptions in EIB/LON systems.
Illustrates the physical connections for LON, EIB, and power supply to the Vitogate 200.
Lists key technical details including voltage, power, IP rating, temperature, and humidity.
Confirms compliance with relevant European standards and directives for the Vitogate 200 EIB.
Specifies that the product is intended for use with Viessmann boiler and heating circuit control units.