EasyManua.ls Logo

Viessmann Vitomax HS M73 - Removing Inspection Port Closures; Removing and Cleaning Turbulators

Viessmann Vitomax HS M73
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Fig. 6
Fig. 7
1. Flue gas collector
1.
Undo screws
A
from insulating fascia
B
and
remove together with thermal insulation mat
C
.
2.
Undo screws
D
and remove cleaning cover
E
.
2. Flame tube entry
Remove screws
F
and pivot cleaning door
G
open.
3. ECO/flue gas hood (option)
Remove nuts
H
and cover
K
.
Removing and cleaning the turbulators (if installed)
B
A
Fig. 8
1.
Without using force, remove turbulators
A
with
turbulator extractor
B
.
2. Clean the turbulators.
Commissioning, inspection, maintenance
Removing the inspection port closures
5837984