Operating Instructions and
User’s Information Manual
VITOROND 200
Vitorond 200
VD2/VD2A Series
Oil- / Gas-fired boiler
Heating input: 490 to 4387 MBH
(144 to 1285 kW)
Do not store or use gasoline or other flammable
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
H Do not try to light any appliances.
H Do not touch any electrical switches, do not use
any phone in your building.
H Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s
instructions.
H If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING
Improper installation, adjustment, and/or
operation could cause carbon monoxide poisoning
resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who
is experienced and qualified in hot water boiler
installation and gas/oil combustion.
WARNING
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

Other manuals for Viessmann VITOROND 200

Question and Answer IconNeed help?

Do you have a question about the Viessmann VITOROND 200 and is the answer not in the manual?

Viessmann VITOROND 200 Specifications

General IconGeneral
ModelVITOROND 200
CategoryBoiler
Heat Exchanger MaterialCast Iron
Fuel TypeOil
ApplicationCommercial
Boiler TypeLow Temperature
Operating PressureUp to 3 bar

Summary

Safety

Safety, Installation and Warranty Requirements

Outlines essential safety, installation, and warranty guidelines for the boiler.

Licensed professional heating contractor

Installation, adjustment, service, and maintenance must be done by a licensed professional.

Carbon monoxide

Improper installation can lead to poisonous carbon monoxide gas.

Equipment venting

Never operate without a proper venting system to prevent carbon monoxide poisoning.

Important Regulatory and Safety Requirements

Working on the equipment

Personnel must be qualified; deactivate power and close valves before service.

Dangerous conditions

Deactivate power and close shut-off valves immediately for safety.

Regular maintenance and service

Regular cleaning and servicing by qualified contractor ensure efficiency and reliability.

For Your Safety

Carbon monoxide

CO is a dangerous gas from incomplete combustion; install detectors.

For safe operation

Frequent checks recommended for debris, pressure, water leaks, and obstructions.

Service and Maintenance