ENGLISH
Contact ViewSonic service team at: http://www.ViewSonic.com or call our service team: United States 1-800-688-6688, Canada 1-866-463-4775
ViewSonic VTMS2431
Other Information
6. Remote Control Pass-through mode
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send
a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that
in this mode the RCU shall have no effect on the monitor function. For example: “+Volume
will not change the volume in the LCD but only sends “+Volume” code to PC over the
RS232 port.
RCU Pass-through Command description:
Length Total Byte of Message excluding “CR”
TV ID Identication for each of TV
Command Type Identify command type,
“p” (0x70h) : RCU Pass-through
Value[1~2] Two bytes ASCII that denes the value
CR 0x0D
RCU Pass-through Command Format:
Reply: (Command Type= “p”)
Name Length ID Command
Type
Value1 Value2 CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5 6 7
Example1: User press “Menu” Key form RCU to TV-03 and RCU data pass-through
to Server, then server will receive “1A”.
Reply (Hex Format)
Name Length ID Command
Type
Value1 Value2 CR
Hex
0x36 0x30
0x33
0x70 0x31 0x41 0x0D
Example2: User press “5” Key form RCU to TV-07 and RCU data pass-through to
Server, then server will receive “05”.
Reply (Hex Format)
Name Length ID Command
Type
Value1 Value2 CR
Hex
0x36 0x30
0x36
0x70 0x30 0x35 0x0D

Other manuals for ViewSonic VTMS2431