35
Gasifying boiler VIGAS
Commission Regulation (EU) 2015/1189,implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to
ecodesign requirements for solid fuel boilers, commission Regulation (EU)2015/1189 supplementing Directive 2010/30/EU of the European
Parliament and of the Council with regard to energy labelling of solid fuel boilers.
Product
information
Symbol Jednotka
16
16 LC
25
25 LC
40
40 LC
60
60 LC
Energy efficiency class
A++
A++
A++
A++
A++
A++
A++
A++
Coefficient of energy EEI
128
128
128
129
128
130
126
128
Seasonal Energy efficiency heating area η
s
%
87
87
87
88
87
89
86
87
Mode stoking manually
Boiler is recommended to operated from a
reservoir least
L 500 500 800 800
1000 1000
1500
1500
Condensing boiler
No
Combined boiler
No
Preffered fuel Chopped wood ,moisture content 20%
Ch
aracteristic when operating with preffered flue
Useful thermal output at rated power P
n
kW
16,0
16,0
25,0
25,0
40,0
40,0
60,0
60,0
Useful efficiency at rated power η
n
% 90,9 92,0 91,4 92,6 91,8 92,95 90,59 92,05
Useful thermal output at minimum output /<50% P
p
kW 8,0 8,0 8,0 7,6 14,4 14,0 26,2 23,0
Useful efficiency at minimum output η
n
% 90,1 90,1 90,6 91,2 90,0 91,67 88,49 90,43
Own electricity consumption at rated power el
max
kW 0,014 0,025 0,022 0,033 0,034 0,045 0,049 0,060
Own electricity at minimum output el
min
kW 0,003 0,014 0,005 0,016 0,005 0,016 0,009 0,020
Own electricity consumption in standby mode P
SB
kW 0,001 0,001 0,001 0,001 0,001 0,001 0,001 0,001
Season emissions of the heating space
1)
PM mg/m
3
18,4 18,7 15,6 14,0 26,6 21,6 18,0 13,4
Season emissions of the heating space OGC
1)
OGC mg/m
3
28,0 25,9 24,7 14,9 26,3 20,2 22,5 12,2
Season emissions of the heating space CO
1)
CO mg/m
3
535,7 529,5 366,0 323,0 410,5 245,8 444,9 450,9
Season emissions of the heating space NOx
1)
NO
x
mg/m
3
147,9 149,6 175,6 164,9 169,1 165,8 148,2 145,6
1) Preffer fuel: Chopped wood, moisture content 20%
Electrical Device Connection Record
(pump, discharge fan, indoor thermostat, expander, etc.)
Date
Device
Service person
name
Certificate no.
Service person
signature
Warranty and after warranty repairs Records
Date
Number of repair
protocol
Service person
name
Certificate no.
Service person
signature
Notes