•Principalfunctions:
- hourly temperature settings in 15-minute steps
- 3 programmable temperature set-points for heating + 3 tem-
perature set-points for cooling + 1 antifreeze level
- weekly programming
- 1 automatic program that may be set by the user (for both heat-
ing and air-conditioning)
- possibility of forcing the program by manually adjusting the tem-
perature
- regulation for both heating and cooling systems
- antifreeze function
- possibility of timed switch off
- remote activation option via telephone dialler
- select between display in degrees Celsius and Fahrenheit
- device reset
•Protectiondegree:IP30
•ClassIIequipment:
•Numberofmanualcycles:3.000
•Numberofautomaticcycles:100.000
•Typeofcontactopening:micro-breakdown
•Typeofaction:1CU
•Trackingindex:PTI175
9. CHARACTERISTICS
• Supplyvoltage:3Vd.c.with2AALR61,5Vbatteries(notinclud-
ed)
•Batterieslife:upto1year
•Output:5(2) A 250 V~ change-over relay output
•Typeofregulation:ON/OFF
•It is possible to create a radio link with actuators 01923 and
01924 by replacing the relay module with the transmitter module
01921.1
•Updatingofdisplaytemperature:every20s
•Ambienttemperaturedisplayrange:0°C+40°C
•Resolutionofthereading:0,1°C
•Resolutionofthesettings:0,1°C
•Precisionofthereading:
- ≤ ±0,5 °C between +15 °C and +30 °C
- ≤ ±0,8 °C at the temperature extremes
•Hysteresis:adjustablebetween0,1°Cand1°C
•Thermostatoperatingrange:
- +4 °C - +15 °C in antifreeze mode
- +5 °C - +35 °C in heating or cooling mode
•Clockaccuracy:≤±1saday