EnOcean multi-function 1-relay actuator (01796.1)
The procedure for selecting the type of operation is as follows:
1) Press the touch button for 8 s (after the first 5 s the device goes into the phase of adding buttons and then into the phase of con-
figuring button management); the LED will blink red for a number of times equal to the current type of operation (1 time for Type 1, 2
times for Type 2, etc.) and will then switch off for 1 s.
2) Release the button.
3) Select the type of operation by tapping on the touch button that will vary the blinking of the LED with a number of switching on/off
equal to the chosen type.
4) Confirm the setting by pressing the touch button for 5 s; the LED will blink green 5 times to confirm the change.
If the procedure is abandoned, after a timeout of 15 s, the actuator will exit this phase without making any changes.
DELETING ALL THE SAVED BUTTONS
To clear all the buttons saved on the actuator, press and hold the touch button for 12 s; in that time the device will go through the
various stages of configuration until the red LED switches on with a steady light, then release the button. Press the touch button again
for another 5 s to confirm; the green LED will blink quickly to confirm the deletion of all the saved devices. If the procedure is abandoned,
after a timeout of 15 s, the actuator will return to normal operation without deleting anything.
CONFIGURING AS A SIGNAL REPEATER
The actuator can be used to extend the range of radio signal coverage and can be configured to level 1 or 2.
To configure the repeat mode, proceed as follows:
1) Press the touch button for longer than 15 s (after the first 5 s the device will go into the phase for adding buttons, configuring man-
agement buttons, deleting all the buttons and finally into the phase of configuring the repeater); the LED will blink red.
2) Release the button.
3) Select the type of repeater by tapping the touch button. Each time you press the button you scroll through the types of repeater; the
number of red blinks indicates the active mode (1 blink Mode 1, 2 blinks Mode 2, etc.).
Mode 1 = Repeater off.
Mode 2 = Repeater on level 1, that is it repeats new messages (ones that have not already been repeated).
Mode 3 = Repeater on level 2, that is it repeats new messages or messages that have already been repeated at least once.
4) Confirm the setting by pressing the touch button for 5 s; the LED will blink green 5 times to confirm the change.
If the procedure is abandoned, after a timeout of 15 s, the actuator will exit this phase without making any changes.
CONFIGURING THE EXTERNAL BUTTON
The actuator can be connected to a traditional switch to control the on-board relay or to control other EnOcean actuators.
The device thus simulates the behaviour of an EnOcean PTM button.
If you need to control other actuators, carry out the following procedure:
1) Enable saving in the remote actuator.
2) Close the traditional switch/push button; the remote actuator will signal saving.
After saving, you can, by opening and closing the traditional switch, control the remote actuator.
INSTALLATION RULES.
Installation should be carried out in compliance with the current regulations regarding the installation of electrical equipment in the
country where the products are installed.
The relay output power circuit must be protected against overcurrents by installing a device, a fuse with a rated breaking capacity of
1500 A or a type-C circuit breaker, with rated current not exceeding 10 A.
REGULATORY COMPLIANCE.
R&TTE directive.
Standards EN 60669-2-1, EN 301 489-3, EN 300 220-2, EN 62479.

Other manuals for Vimar Arke

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vimar Arke and is the answer not in the manual?

Vimar Arke Specifications

General IconGeneral
TypeSwitch
RangeArke
SeriesArke
BrandVimar
MaterialThermoplastic
ColorVarious
Current16A
Protection DegreeIP20
MountingFlush

Related product manuals