35
EN
13F4, 13A4, 13A4.B - 13F7, 13A7, 13A7.B
control signals, i.e. activated at the same time as others, for
example the lock release of a different electronic unit (see lock
/ F1 / F2 Common, paragraphs 4.4, 4.5, 4.6).
Use buttons
and or the numeric keypad to select the
identifier of the indoor unit to which to apply the enabling and
confirm with
. Once found, enter changes with . Using
buttons
1
to
6
MNO
enable the controls, see Table 8.
Note: using the numeric keypad to select the ID in vertical con
-
figuration type in the number of the indoor unit (between 1 and
200) and between 201 and 204 for concierge switchboards. In
horizontal configuration, type in the code of the indoor units
delimited by the window and valid in relation to the number of
indoor units per router, see table 3 (provided on the following
pages), or type in the IDs of switchboards between 40001 and
40008, which by default correspond to the IDs of the switch
-
boards of router 1 and router 2, otherwise the IDs among those
configured in Switchboard position (see paragraph 4.2).
BUTTON ACTION
1
Direct lock
2
ABC
F1 direct
3
DEF
F2 direct
4
GHI
Common Lock
5
JKL
F1 common
6
MNO
F2 common
Table 8
It is possible to set enabling and disabling simultaneously for
all the indoor units, for one or more outputs. The procedure is
described below, but you should use the configuration software
for a PC.
For the first digit to choose the indoor unit press
0
+
. The dis-
play will show the confirmation request.
The numeric keys now have the following meaning:
BUTTON
DISPLAY
DIRECT
ACTION
COMMON
ACTION
0
+
Nothing
changes
Nothing
changes
1
Sets to default
the DIRECT
enabling of
lock, F1, F2, ie
enables all
Sets to default
the COMMON
enabling of
lock, F1, F2, ie
disables all
BUTTON
DISPLAY
DIRECT
ACTION
COMMON
ACTION
2
ABC
Sets to default
the DIRECT
enabling of
the lock, ie
enables them
Sets to default
the COMMON
enabling of
the lock, ie
disables them
3
DEF
Sets to default
the DIRECT
enabling of
F1, ie enables
them
Sets to default
the COMMON
enabling of F1,
ie disables
them
4
GHI
Sets to default
the DIRECT
enabling of
F2, ie enables
them
Sets to default
the COMMON
enabling of F2,
ie disables
them
5
JKL
Removes
from default
the DIRECT
enabling of
lock, F1, F2, ie
disables all
Removes
from default
the COMMON
enabling of
lock, F1, F2, ie
enables all
MNO
Removes
from default
the DIRECT
enabling
of lock, ie
disables them
Removes
from default
the COMMON
enabling
of lock, ie
enables them
7
PQRS
Removes
from default
the DIRECT
enabling of F1,
ie disables
them
Removes
from default
the COMMON
enabling of
F1, ie enables
them
8
TUV
Removes
from default
the DIRECT
enabling of F2,
ie disables
them
Removes
from default
the COMMON
enabling of
F2, ie enables
them
9
WXYZ
Switches to
Common. The
rst letter of
the second line
becomes C.
Switches to
Direct. The
rst letter of
the second line
becomes D.
Default = direct commands enabled, indirect commands
disabled
4.0 - Entrance panel chime repetition
Enables repetition of the chime in the speaker of the electronic
unit. Press
1
to activate the chime; press
0
+
to deactivate
it. Press
to confirm the change.
Default = Yes
4.1 - Number of chime cycles
Following the transmission of a call, the electronic unit (see par-