CONTROLS : PLUG IT IN (wait one minute) and ENJOY!
DEFAULT SETTINGS : Storage Temperature : 57°F / 14°C (ideal temp for wine cellaring)
Fan Speed: DEFAULT. Optimized for maximum efciency and moderate noise
Display: SET - POINT (°F)
FEATURES: Digital Sensor: Sensing ACTUAL TEMP (air in cabinet)**
Set temp range: 50°F / 72°F (check humidity levels and lower
temperatures from default only if conditions allow dialing unit
below 57ºF could cause a water leak or overow in high humidity
conditions.
Selectable modes: QUIET, DEFAULT, EFFICIENT
Dual display: °F / °C
Press
TO SEE CABINET TEMP. :
OPERATION
SET
ADJUST
1 OUT 2
Drobot Controls
TM
Press Release
SET
SET POINT :
Unplug / Re plug the unit, but rst eliminate the possible cause; inspect the seals
of the door and cabinet, reduce ambient temperature, remove obstructions on the
exhaust side.
Press and together NOTE : All other settings, reset to DEFAULT
Press and together to display the default offset, then
Press or once per degree to offset the display temperature.
TO RESET FROM ALARM :
TO CHANGE FROM °F TO °C :
TO CALIBRATE :
SET
DEFAULT TO EFFICIENT :
EFFICIENT TO QUIET :
QUIET TO DEFAULT :
Press and hold for 5 sec. until the unit will stop and store the request *
Press and hold for 5 sec. until the unit will stop and store the request *
Press and hold for 5 sec. until the unit will stop and store the request *
* The unit will restart after 1 minute in the selected mode or a higher one as required
by the temperature conditions.
SET
SET
SET
TO CHANGE FAN SPEED :
NOTE : Automatic modes are disabled during the rst 4 hours after plug in.
QUIET
DEFAULT
EFFICIENT
EMERGENCY
ALARM
Quiet operation, slowest fan speed, least efcient, with usually longer cycles.
* USE AT YOUR OWN RISK AND ONLY WHEN AMBIENT CONDITIONS ARE IDEAL.
Optimal noise, efciency, cycle time balance
Higher fan speed, best performance if noise is not an issue.
* USE THIS SETTING WHENEVER AMBIENT CONDITIONS ARE WARM OR HUMID
(ABOVE 50%R.H.)(ABOVE 75ºF).
Higher fan speeds, unit will automatically operate with higher fan speed if out of
set-point range
The unit will shut down in case the cabinet temperature exceeds 72 °F
Press Release
Then, press or once per degree. The unit will memorize the
new value and
it will restart after 1 minute delay.
SET
TO CHANGE SET POINT :
** Reading AIR temperature the
controller will respond more quickly
to temperature changes than using a
LIQUID probe. As in any refrigerator
air temperature may change 7 or
8 degrees during a complete cycle,
however, the wine temperature,
will remain constant, within one
degree Farenheit.