EasyManua.ls Logo

Virax VIPER P22+ - VIPER P22+ Technical Data; Main Safety Warnings for VIPER P22+; Work Zone Safety Guidelines

Virax VIPER P22+
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Caption
The tool bears a label describing special signs. These provide important information about the product or instructions of use.
Compliance with European safety standards. Read the original manual.
Wear glasses. Wear gloves.
2 Technical data
NOTES:
Carefully read the instructions before using this tool.
The manufacturer reserves the right to improve his products and change their specifications without
special notice.
The specifications may vary according to the country.
3 Main safety warnings for the tool
WARNING:

electric shock, fire and/or severe injury.

the warnings, the term « tool » refers to your power tool supplied by battery.
3.1 Work zone safety

AND PROPERLY LIT AT ALL TIMES.
Poorly lit or cluttered zones are sources of accidents.
Model
VIPER P22+
Reference
253620
Force delivered by the machine to guarantee crimping
Min 32 kN; Max.35 kN
Battery supply
14.4V DC 2.5 Ah Li-ion 36 Wh
Power absorbed
300 W
Crimping capacity:
For PER / PEX tubes:
Ø 12 to Ø 32 mm.
For Multilayer tubes:
Ø 12 to Ø 110 mm.
For steel tubes (stainless steel or galvanized):
Ø 12 to Ø 54 mm.
For copper tubes:
Ø 12 to Ø 54 mm.
Crimping cycle time:
For dimensions Ø12 - Ø40 mm
3-6s
For dimensions Ø40 - Ø110 mm
7-9s
Jaw rotation
320°
Weight (without battery ; without jaw / with battery ; without jaw)
3.6 / 4.2 kg
Machine size with battery ; without jaw
length / height / width (mm)
408 / 321 / 85
Dimensions of the case length / height / width (mm)
594 / 494 / 149
Safety disengagement
Yes: electronic
Information on sound and vibration emissions
Sound emission:
Acoustic pressure level at operator ears: LpA
78 dB (A)
Peak acoustic pressure level at operator ears: LpCrête
94 dB (C)
Acoustic power level: LwA
85 dB (A)
Uncertainty KpA
2.5 dB
As per standard NF EN ISO 15744 tests on work cycles without part
Vibration emission
Weighted hand-arm acceleration values m/s²
On the trigger
0.54 m/s
Second hand at front
0.76 m/s
Estimated uncertainty
As per standard NF EN ISO 20643 tests on work cycles without part
0.2 m/s

Table of Contents