EasyManua.ls Logo

VisAccess AXS-100 User Manual

Default Icon
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AXS-100 Slave Controller
For AXS-100 and AXS100XT Access Control Systems
Installation Guide
Introduction
The AXS-100 Slave Controller is a cost effective solution that
extends AXS-100 or AXS100XT access control system
functionality up to 16 doors on a single RS-485 data loop using
any combination of up to *8 ‘Master’ or ‘Slave’ controllers.
Each AXS-100 slave controller operates in real-time with
distributed intelligence and a full mirror database for offline
conditions. Should a communication failure occur between any of
the slaves and the master controller or between the master
controller and the host computer, each AXS-100 slave controller
will continue to function normally with no degradation in
performance and response times of card reading, alarm
activation or activation of logic events. Each AXS-100 slave can
also monitor the status of the protected doors (open or closed)
and the status of the door locks (locked or unlocked).
Initial system configuration is programmed via the master
controller’s keypad. Functionality such as event log access, card
holder programming and/or mode updates are handled via EIRIS
V4.6 (or higher) or AXSalert enterprise software.
*One ‘Master controller’ is required for each RS-485 data loop.
CAUTION: It is important that you read, understand, and
follow the instructions in this document. If you have
questions, call your local VT support representative.
1. Mounting and Initial Assembly
A. Metal Box Mounting
The AXS-100 Slave Controller must be installed indoors, within
the protected premise, in accordance with the National Electrical
Code (NFPA70) and the local authorities having jurisdiction.
Note: Do not connect (the transformer) to a power receptacle that
is controlled by a switch.
B. Backup Battery Installation (Optional)
Locate the optional backup battery (12V, 7.0Ah, Lead-acid
battery) in the lower left side of the system enclosure (see fig. 2).
Backup
battery
(optional)
Fig. 2 - Backup Battery
Page 1 of 6
DE62821A_V7.0
Question and Answer IconNeed help?

Do you have a question about the VisAccess AXS-100 and is the answer not in the manual?

VisAccess AXS-100 Specifications

General IconGeneral
BrandVisAccess
ModelAXS-100
CategoryIP Access Controllers
LanguageEnglish

Summary

AXS-100 Slave Controller Introduction and Mounting

AXS-100 Slave Controller Introduction

Explains the AXS-100 Slave Controller's role in extending system functionality and its offline capabilities.

Mounting and Initial Assembly

Details the process for mounting the AXS-100 Slave Controller indoors using a metal box.

AXS-100 Slave Controller Installation and Wiring

Metal Box Door Lock Assembly

Explains the assembly of the door lock for the system's metal box.

Tamper Switch Installation and Wiring

Details the installation and wiring of a tamper switch to protect the controller against tampering.

Panel Wiring and Connections

Covers connecting proximity readers, inputs, and electric locks to the controller.

AXS-100 Controller Configuration and Setup

Controller ID Assignment

Details assigning a unique ID address to the slave controller using DIP switches.

RS-485 Data Loop Configuration

Details setting up the RS-485 data loop for AXS-100 Master-Slave systems and daisy-chaining.

AXS-100 Maintenance, Specifications, and Compliance

Maintenance Procedures

Outlines monthly checks and provides instructions for handling lithium batteries.

Specifications and Ordering Information

Provides technical specifications for the AXS-100 Slave Controller and ordering details.

Standards Compliance

Details FCC and EU compliance for radio and telecommunications terminal equipment.

Product Warranty

Outlines the one-year limited warranty for Visonic Technologies products, excluding batteries.