D-302416 KF-234 PG2 Installation Instructions 3
5. TESTING A NEW UNIT
Since the KF-234 PG2 is supplied with the battery already installed, the unit is practically ready to be tested.
A. Stand 3 m (10 ft) away from a target control panel (or wireless control panel) and press the ARM AWAY button (see Fig. 1).
Verify that the red LED lights upon transmission and that the green LED lights upon acknowledgement from the control panel.
B. Make sure that the control panel responds as programmed and as stated in the control panel’s instruction manual.
6. PRODUCT LIMITATIONS
Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range
(required by FCC and other regulatory authorities), there are some limitations to be considered:
A. Control panels may be blocked by radio signals occurring on or near their operating frequencies, regardless of the code selected.
B. Wireless equipment should be tested regularly to determine whether there are sources of interference and to protect against faults.
7. COMPLIANCE WITH STANDARDS
Compliance with Standards
Europe: EN 300220, EN 50131-1 Grade 2, Class II and (EN 50134-2 Class II if used for social
alarm), EN 301489, EN 50130-4, EN 60950, EN 50131-6
The KF-234 PG2 is compatible with the RTTE requirements - Directive 1999/5/EC of the European
Parliament and of the Council of 9 March 1999 and EN50131-1 Grade 2 Class II.
Certified by the Dutch testing and certification body Telefication BV.
USA: CFR 47 Part 15 (FCC)
Canada: RSS 210
The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in
the technical brochure. This functionality has not been tested to comply with the respective technical requirements and
should therefore be considered outside the scope of the product’s certification.
EN 50131-1 Security Grade
Grade 2
EN 50131-1 Environmental Class
Class 2
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Compliance Statement
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference,
which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the
following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment.
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received
or that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
The technical documentation as required by the European Conformity Assessment procedure is kept at:
UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL.: +44(0)845 0755800 FAX: +44(0)845 0755801
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

Other manuals for Visonic KF-234 PG2

Related product manuals