1. INTRODUCTION
The SR-730 PG2 is a fully wireless outdoor siren, designed for
installation in areas in which wiring action is difficult or impossible.
The siren is compatible with PowerG control panels.
Features
Siren and strobe light activation: When an identified event
message is received from the compatible PowerG alarm
system, the siren activates its sounder & strobe light.
Notes: The sounder is activated for a predefined "Bell Time"
(refer to the control panel Installer Guide), according to local
authorities requirements, or until the system is disarmed,
whichever occurs first.
The strobe light operates as described in the PowerG Installer
Guide.
Tamper indication: In case of tamper while the system is
armed, the siren transmits the message to the alarm system
and then the alarm system determines whether the siren
should be activated or not. If the siren does not receive an
acknowledge message from the alarm system, the siren will
function independently.
Low battery voltage alert: When the battery voltage is low, a
low battery message is sent to the alarm system. After the low
voltage message delivery, at least 2 siren alarms are possible
before the siren is totally inactive.
Power Supply Options: Non-rechargeable battery. Optional -
two non-rechargeable batteries.
Sound Types: Burglar (between 1400Hz - 3200Hz), fire,
gas(CO) and flood.
Entry/Exit: Exit delay beeps sound once the user has armed
the system. Entry delay beeps sound once the user has
entered the protected area. (Entry/exit beeps can be enabled /
disabled from the control panel Installer menu.)
Squawk indications: Squawk (beep) sounds can be used to
indicate alarm system arming (1 squawk) and disarming (2
squawks) by a keyfob (squawk can be enabled from the control
panel User menu).
Strobe Light Color: The siren can be purchased with red,
blue, amber or transparent lens, according to the desired
strobe light color.
Siren activity LED: A flashing LED (optional, at the bottom of
the siren front panel) indicates siren activity (can be disabled
by the control panel)
Double Tamper protection: When the siren front panel is
removed or when the siren is removed from the wall, tamper
alarm is sent to the alarm system.
IMPORTANT! The SR-730 PG2 siren must be installed on the
wall in a vertical position with the screw pointing to the floor
only, as illustrated in Figure 1b. The importance of correct
positioning of the SR-730 PG2 is to enable the siren to function
as a waterproof device.
2-way full supervision
The siren is fully supervised, 2-way communication device. It
includes a receiver, to receive event messages from the alarm
system, and a transmitter, to periodically transmit its status signal
to the alarm system.
A
Fig. 1a - External View A. Wall
Fig. 1b – Mounting Position
Self-test feature
Upon pressing the self test switch, siren functional check is
performed - low level sounds and flash light indicate that the siren
is serviceable.

Other manuals for Visonic SR-730 PG2

Question and Answer IconNeed help?

Do you have a question about the Visonic SR-730 PG2 and is the answer not in the manual?

Visonic SR-730 PG2 Specifications

General IconGeneral
TypeWireless Outdoor Siren
CompatibilityPowerMaster systems
Two-way CommunicationYes
PowerG TechnologyYes
Visual IndicationStrobe light
Ingress ProtectionIP55
Tamper SwitchYes
Transmission Frequency868 MHz

Summary

1. Introduction to the SR-730 PG2 Siren

Product Features Overview

Details siren activation, tamper, battery, power, sound types, entry/exit beeps, squawk, strobe color, activity LED, double tamper protection, and supervision.

Self-Test Functionality

Explains how to perform a self-test to check siren operational status via sound and light indicators.

2. Installation Guide for SR-730 PG2

Installation Steps and Notes

Covers physical installation steps, mounting procedures, battery and power connections, and essential setup notes.

Important Safety Warnings

Provides critical warnings regarding RF exposure compliance and safe battery handling during installation.

4. SR-730 PG2 Device Settings Configuration

Siren Configuration Parameters

Detailed settings for strobe alarm, exit/entry beeps, squawk, sounder volume, activity LED, and auto tamper alarm.

5. Local Diagnostics Test Procedure

Testing Procedure and Signal Strength

Outlines the steps for performing local diagnostics, interpreting LED responses for signal strength, and ensuring reliable reception.

6. Compliance with Standards

Regulatory Compliance and Recycling

Details applicable standards (EN, FCC, IC), FCC statements, and WEEE product recycling declaration.

7. Technical Specifications of SR-730 PG2

Specifications Overview

Lists key technical details including frequency band, modulation, power supply, battery type, dimensions, and operating conditions.

Related product manuals