4 DE5110
Entry Delay:
Programmable, 0 to 99 seconds.
Special Functions:
Zone bypass, force arming, false alarm
cancellation
Data Retrieval:
Alarm memory and trouble indications
Test Modes:
Walk, Bell/Siren/Battery, Keypad, Communicator
Alarm Relay Contact Ratings:
5A @ 24 Volts (SPDT).
Supply Voltage:
230 VAC (115 VAC optional).
Power Transformer AC Output:
16 VAC, 40 VA.
Auxiliary DC Output (via the 12VDC terminals):
12 VDC, 700
mA max.
Siren/Bell DC Output (via the V-BELL jumper):
3 A max.
Maximum Number of Keypads:
4
Keypad Current Drain (Max.)
KP-1001/8 & KP-1001/16:
35 mA
KP-1002:
45 mA
KP-1003:
60 mA
PGM Output Current Sinking Capability:
100 mA max.
Fuse Ratings:
230 VAC input -
315 mA (time lag type T315 mA/250V
5X20mm)
12 VDC for detectors, keypads and accessories -
1A;
12 VDC supply for bell -
3A;
Siren driver
- 1.5A.
Standby Battery:
Lead-acid type, 12 V, up to 6 Ah.
Charging Current:
Electronically limited to 300 mA
&RPPXQLFDWRU &KDUDFWHULVWLFV
Programmable Central Station Telephone Numbers
Channel 1: One first priority number and one backup number
Channel 2: One second priority number and one backup number
Programmable Private Telephone Numbers: One temporary
"follow me" number, 3 "permanent" numbers
Phone Number Length: 16 digits max, including hexadecimal
digits for pauses
Dialing Methods: DTMF or Pulse, as programmed
Mark/Space Value Options - 40/60, 34/66, 60/40, 66/34
Central-Station Related Parameters
Communication Protocols:
DTMF protocol (at the rate of 10 digits per second),
Tone pulse protocol with data/handshake tones of 1900/1400 or
1800/2300 Hz
Additional protocols in future versions.
Data Rate Options (for tone pulse protocol): 10, 20, 33, 40 pps
Data Verification Options: Double round or Checksum
Report Types: Alarm/restore, arm/disarm and system
maintenance events
Report Destinations: Any report type may be linked to any one
of these reporting destinations – 1st channel only, 2nd channel
only, 1st and 2nd channels or none altogether.
Protocol Formats: 3/1, 3/2, 4/1, 4/2 and 4/2 + checksum.
Private-Telephone Related Parameters
Report Types: Regular alarms (two-tone siren) and 24-hour
zone alarms (swept-tone siren).
Report Destinations: All 4 telephones or none altogether.
6LUHQ 'ULYHU 'DWD
Alarm signal: Continuous swept-tone siren (all alarms except
FIRE); pulsating swept-tone siren (FIRE).
Output Power: 10 W max.
Loudspeaker Impedance: Not less than 4 ohms
3K\VLFDO 3URSHUWLHV
Operating Temperature Range: 0°C to 49°C (32°F to 120°F)
Storage Temperature Range: -20°C to 60°C (-4°F to 140°F)
Dimensions (H x W x D):
Metal Cabinet: 262 x 315 x 74 mm (10-5/16 x12-3/8 x2-15/16 in.).
Keypads (all models): 159 x112 x 30 mm (6-1/4x4-3/8 x1-3/8 in.).
Optional UPB-3 Cabinet: 165x108x38mm(6-1/2x4-1/4x1-1/2 in.).
Weight:
Metal Cabinet with Control Module & Communicator:
2.180 kg (4.8 lb).
LED Keypad KP-1001: 224 g (7.9 oz)
Medium LCD Keypad KP-1002: 253 g (8.9 oz)