VIVAX ENG
40
on process will immediately stop. However, the fan motor will continue to
operate (this is normal). Carefully move the unit to a drain location, remove
the bottom drain plug and let the water drain away. Reinstall the bottom drain
plug and restart the machine until the "P1" symbol disappears. If the error
repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug before using the unit
When the water level of the bottom tray reaches
a predetermined level, the unit beeps 8 times,
the digital display area shows "P1" . At this time
the air conditioning /dehumidification process
will immediately stop. However, the fan motor
will continue to operate (this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the water
drain away. Reinstall the bottom drain plug and
restart the machine until the "P1" symbol
disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug
firmly to prevent leakage before using the unit.
Care and Maintenance – air filter cleaning
IMPORTANT:
DO NOT operate the unit without filter because dirt and lint will clog it and
reduce performance.
Removal:
This unit has upper and lower filters. Take the upper filter out along the the
arrow direction. Remove the lower filter by loosening the screw(if any),
taking out the filter as shown.
Continous drain hose
MODEL A1
Lower filter A
(press the grill
down slightly
and pull filter
out)