Installation Manual
Thermostat Application Guide
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Heat Only Systems
Cool Only Systems
Millivolt
Yes
Yes
Yes
Yes
Yes
No
Power Type
Hardwire - 24 VAC
Common Wire
Table of Contents
Installation Tips
Thermostat Quick Reference
Private Label Badge
Wiring
Wiring Diagrams
Technician Setup Menu
WIFI Tech Setup
Programming
Features
Specications
Page
A trained, experienced
technician must install this
product.
Carefully read these
instructions. You could damage
this product or cause a
hazardous condition if you fail
to follow these instructions.
Una version en español de este
manual se puede descargar en
la pagina web de la compañia.
Rev. 1821
U.S. Registered Trademark. Patents pending
Copyright 2018 All Rights Reserved.
5-7
8
13-19
2-4
Yes
Yes
20
Mount Thermostat
Align the 4 tabs on the subbase with
corresponding slots on the back of the
thermostat, then push gently until the
thermostat snaps in place.
Installation Tips
Note: To ensure a solid t between the
thermostat and the subbase:
1. Mount subbase to a at wall
2. Use screws provided
3. Drywall anchors should be ush with the wall
4. Wires should be pushed into the wall
Installation Tips
The thermostat should be installed approximately 4 to 5 feet above the
oor. Select an area with average temperature and good air circulation.
• Close to hot or cold air ducts
That are in direct sunlight
With an outside wall behind the thermostat
• In areas that do not require conditioning
Where there are dead spots or drafts (in corners or behind doors)
Where there might be concealed chimneys or pipes
Wall Locations
Pick an installation location that is easy for the user to access. The temperature
of the location should be representative of the building.
Installation Tip
Do not install thermostat in these locations:
Installation Tips
21-28
31
Vertical Mount
Horizontal Mount
For horizontal mount put one screw on
the left and one screw on the right.
All of our products are mercury free. However, if the product you are
replacing contains mercury, dispose of it properly. Your local waste
management authority can give you instructions on recycling and
proper disposal.
Mercury Notice
Failure to disconnect the power before beginning to install this product
can cause electrical shock or equipment damage.
Installation Tip: Electrical Hazard
For vertical mount put one screw on
the top and one screw on the bottom.
Subbase Installation
11-12
9-10
29-30
Vive Comfort
Toll Free : 888-776-1427
Web: www.vivecomfort.com
Hours of Operation: M-F 9AM - 6PM Eastern
TP-S-855i
MENU AUTO HEAT
P.O. Box 3377
Springeld, MO 65804

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vive Comfort TP-S-855i and is the answer not in the manual?

Vive Comfort TP-S-855i Specifications

Temperature Control IconTemperature Control
display range of temperature41˚F to 95˚F (5˚C to 35˚C)
control range of temperature44˚F to 90˚F (7˚C to 32˚C)
swing (cycle rate or differential) heating0.2˚ to 2.0˚
swing (cycle rate or differential) cooling0.2˚ to 2.0˚
Power IconPower
load rating per terminal1 amp
load rating maximum all terminals combined1.5 amp
power source18 to 30 VAC, NEC Class II, 50/60 Hz
Operating Environment IconOperating Environment
operating ambient temperature32˚F to +105˚F (0˚C to +41˚C)
operating humidity90% non-condensing maximum
Connectivity IconConnectivity
wifi frequency range2.4 GHz ISM radio band
wifi standards supported802.11 B/G/N
Weight and Dimensions IconWeight and Dimensions
dimensions of thermostat4.7” W x 4.3” H x 0.9” D